Products Search
Product categories

CRF2-S Sanitizing Fogger

Why the CRF2-S is a valuable Sanitizing Fogger

  1. Hydrogen Peroxide is a well known sterilant purchased from your local chemical supplier. H2O2 is quite effective against Coronavirus, fungi, spores, molds, bio-organisms
  2. Low Cost ultrasonic fogger requires 110 VAC or 220 VAC, provides 3000 cubic feet area decontamination / cycle
  3. Hydrogen Peroxide can be used from a 3.5% mixture up to a 35% mixture in distilled water, depending on what level of decontamination is specified. NO RESIDUE LEFT BEHIND!
  4. Use 1 CRF2-S to carry easily from room to room, no dragging compressor lines
  5. Use in Hotels, small Business offices, medical rooms, police cars, taxis, Car Wash
  6. Much more effective than low cost back pack liquid sprayers, electrospray hand foggers and converted humidifiers, which are not  capable of sanitizing your home, office or work area. These devices leave surfaces sprayed with low grade sterilants, but do not sanitize walls and air in the room; leaving dry chemical residue all over the surfaces sprayed allowing adults, children, employees, pets to ingest and enter the eyes and mouth through body contact

 

The CRF2-S sanitizing fogger generates a sterilant fog at about 10 micron droplet diameter, which evaporates to create an exponentially larger sterilant fog floating into the room air with about 3,000 cubic feet per cycle to sanitize all open surfaces and air in that closed room/area. The primary focus of the CRF2-S is to sanitize against coronavirus in smaller rooms, using the preferred sterilant as specified by the customer.  If you are considering a low cost spray gun, consider this. Spray guns emit droplets at 25 to 75 microns in droplet size, allowing the spray droplets to be pulled down by gravity to the surfaces, leaving Sterilant residue at high levels on all surfaces for your employees or kids and pets to drag their hands across? We understand costs, but if you want an effective virus killer, consider the very effective CRF2-S Sanitizing Fogger using the certified Minncare sterilant to produce a floating fog to expand to about 3,000 cubic foot sterilant vapor to contact all surface areas and air in the room. That is how you protect your employees or kids and pets, leaving NO RESIDUE behind, yet killing spores, molds, fungi, viruses, envelope viruses and bio-organisms?

 

The CRF2-S Sanitizing Fogger uses 9 ultrasonic piezo devices to generate 0.26 cubic meters of pure fog per minute at a droplet size of about 10 microns, which floats in the air to provide a visible sanitizing fog. The sterilant fog then evaporates to a 3,000 cubic foot vapor to contact surfaces, on tables, under computers, on walls, ceilings, light fixtures, etc, with the purpose of killing unwanted bio-organisms. Killing unwanted spores, envelope viruses, molds, fungus can be achieved using a Minncare sterilant to protect and sanitize medical rooms, sterile rooms, business offices, most working areas and industrial areas. The CRF2-S is especially useful to combat viruses such as the coronavirus COVID-19. The CRF2-S can be remotely controlled by a 10 foot remote power cable. The CRF2-S can use a solution of Hydrogen Peroxide mixed into distilled water. Do not use ordinary tap water due to chlorine content. The CRF2-S provides a constant fog volume during a typical 50 minute cycle.

Title Range Discount
Quanitity Discount 3 + 10%
Discounts are available for purchases of quantity 5 or more.

CRF2-S Decontaminating Fogger generates ≈ 0.26 cubic meters of visible sanitizing fog / minute, which evaporates and exponentially expands to cover ≈ 3,000 cubic feet per sanitizing cycle of 50 minutes. The CRf2-S uses a solution of hydrogen peroxide in purified water or distilled water to sanitize a closed area from unwanted bio-organisms, such as envelope viruses, bacterial growth, molds, spores, fungus and bio-organisms.

The CRF2-S is a portable, sanitizing fogger, using a solution of distilled water and H2O2, hydrogen peroxide to generate about 0.26 cubic meters of sanitizing fog per minute, which begins to evaporate about 6 feet distance, exponentially expanding to a sanitizing vapor to cover about 3,000 cubic feet  to decontaminate bio-organisms in small business offices, medical rooms, work areas and industrial areas. If you are comparing hand sprayers and electro-sprayers to the CRF2-S, how much fog volume does the other fog generator produce and how big are sprayer liquid droplets, compared to the 10 micron vapor droplets of the CRF2-S? The CRF2-S provides constant fog volume and provides a 10 foot, power on/off remote cable. The CRF2-S would be used in bio-decontamination of small medical rooms, homes, business offices, police vehicles, ambulances, EMT vans, etc.

CRF2 - Click here for Cleanroom Fogger Video

Sanitizing Areas for Your Employees, or as a SERVICE to Your Customers

The CRF2-S produces a visible aerosol fog at about 10 micron droplet diameter, which is the right size of droplet to float in the air. The droplets exit at a constant fan speed. As the aerosol sterilant is pushed into the air, it begins to evaporate to a vapor at an exponential rate, which further accelerates the sterilant into all areas up to 3,000 cubic feet (87 cubic meters per cycle, killing spores, fungus, envelope viruses, molds, fungus, etc. The CRF2-S can be directly controlled or operated via a 10 foot remote power cable.

Compare CRF4-S and CRF2-S and DF2S Dry Foggers

(Details)

Product Model CRF4-S Decontaminating Fogger CRF2-S Decontaminating Fogger DF2S Decontaminating Dry Fogger
FOG Minutes ~ 45 minutes ~ 50 minutes ~ 90 minutes
FOG, Cubic Meters/Min. ~ 1.25 Cubic Meters/Min., visible ~ 0.26 Cubic Meters/Min., visible ~ 11.1 Cubic Meters/Min., not visible
Total Sterilant Vapor Volume @ 1 Cycle ~ 10,000 cubic feet (285 cubic meters) per cycle. Refill and Restart as needed. ~ 3,000 cubic feet (57 cubic meters) per cycle. Refill and Restart as needed. ~ 35,000 cubic feet (1000 cubic meters) / cycle. Refill and Restart as needed.
Typical volume of sterilant used per cycle
3.325 liters of H2O2 (@ 35% mixture) in 6.175 liters distilled water, total 9.5 liters liquid fill 1.323 liters of H2O2 (@ 35% mixture) in 2.427 liters distilled water, total 3.78 liters liquid fill 1.54 liters Minncare (@ 7% mixture) in 20.46 liters purified water, total 22 liters liquid fill.
Aerosol Fog Droplet size ~ 8 microns ~ 9-10 microns ~ 7.5 microns
Typical Sterilant Used
H2O2, Hydrogen Peroxide H2O2, Hydrogen Peroxide Minncare EPA Reg. NO.: 52252-4; EPA Est. NO.: 52252-MN-01
Adjustable Airflow Velocity and Fog Volume
Yes, thru touch pad and wireless remote control, as well as remote On/Off using Wireless No airflow control, constant fog volume output Constant fog volume output, controlled by air compressor, (dry air compressor recommended)
Fogger Technology Ultrasonic creates sterilant fog @ 8 micron droplet which exponentially evaporates to a 10,000 cubic foot sterilant vapor Ultrasonic creates sterilant fog @ 9-10 micron droplet which exponentially evaporates to a 3000 cubic foot sterilant vapor Aerosol + Evaporation creates sterilant fog, which evaporates to sterilant vapor
Water Used Distilled water is ideal or De-ionized Water, WFI water or sterile water. Tap Water should not be used due to chlorine in tap water. Distilled water is ideal or De-ionized Water, WFI water or sterile water. Tap Water should not be used due to chlorine in tap water. Distilled water is ideal or De-ionized Water, WFI water or sterile water. Tap Water should not be used due to chlorine in tap water.
Where used
Medium sized office areas, medical rooms, hospital rooms, work areas Small office areas, medical rooms, hospital rooms, work areas Large office areas, medical rooms, hospital rooms, work areas, warehouses
Autoclavable No No Yes, Autoclavable
Compatible Guidelines ISO 14644-3, USP 797 ISO 14644-3, USP 797 ISO 14644-3, USP 797
Compatible Guidelines Check with Local/State Health for any compliance requirements Check with Local/State Health for any compliance requirements Check with Local/State Health for any compliance requirements
Dry Compressor Requirements
No, CRF4-S includes onboard fan control and volume control No, CRF2-S includes constant fan output DF2S requires external Dry Air Compressor at 70-100 psi
Total Deionized/Sterile Water and Sterilant Volume 9.5 liters 3.75 liters 22 liters
Typical Sterilant Concentration
H2O2 is purchased from your local chemical supplier and mixed from 3.5% to 35% solution in distilled / purified water H2O2 is purchased from your local chemical supplier and mixed from 3.5% to 35% solution in distilled / purified water Minncare Sterilant is mixed from 3 % to 10 % in purified water
Operator Control Touch pad control of fog volume & airflow Power Switch, no fog controls Operated by separate Dry Air Compressor
Remote Control Wireless Remote control of fog volume & airflow Remote Cable Control, 10 feet No Wireless Remote Control of fog
Handling Carry Handles (top and front) Carry Handle (top) Carry Handle
Enclosure 316L Stainless Steel, electro-polish Polyethylene Enclosure 316L Stainless Steel, electro-polish
Power VAC 120, 220, 100 VAC 120, 220 VAC 120, 220, 100 VAC to Compressor only
Full Weight ~ 65 lbs ~ 20 lbs ~ 110 lbs
Accessories 12 Accessories quoted/suggested 8 Accessories quoted/suggested 12 Accessories quoted/suggested

Sanitizing Fogger, Decontaminating Fogger

The CRF2-S is a portable sanitizing and decontamination fogger is designed with a polyethylene enclosure, which is resistant to most environments. The CRF2-S Fogger produces a 10 micron fog which quickly evaporates to spread into an area of interest, allowing the sterilant to come into contact with open surfaces of bio-organisms to kill unwanted viruses, envelope viruses, spores, molds, fungus. CRF2-S ships in a rolling, carry case with handle and wheels to protect the sanitizing  fogger during transit and storage, when moving from location to location. Hydrogen Peroxide is used in the CRF2-S most often as a sterilant. H2O2 is found in nearly every home and is quite effective against unwanted bio-organisms. Hydrogen peroxide can be purchased at your local pharmacy, along with Distilled water. A Drain and Dry kit is included in CRF2-S package to easily drain the sterilant after use, and then to dry CRF2-S out before storing the fogger in the rolling carry case.

CRF2-S Technology

CRF2 uses 9 ultrasonic piezo devices to generate a pure visible sterilant fog of 0.26 cubic meters / minute, which exponentially evaporates to a sterilant vapor covering up to 3000 cubic feet, allowing the sterilant to come into contact with bio-organisms in that 3000 cubic foot area, in the air and on available surfaces.

SANITIZING FOGGER INFORMATION

The CRF2-S can be turned on or off at will, and refilled with Deionized water, Sterile Water or WFI Water as needed. The fog volume is constant. The only maintenance is to drain water and to air dry the water cavity immediately after each fog study.

In order to create larger volumes of fog, 9 ultrasonic devices are used, which vibrate at high frequencies, generating high volumes of vapor droplets at a diameter of 10 microns. The CRF2-S produces about 0.26 cubic meters of visible sanitizing fog, which evaporates to about 3000 cubic feet if the unit is run for a typical 50 minute cycle.

The transducer life is ~3,000 hours. To protect the transducers from damage there is a level sensor that will interrupt the input voltage to the transducer module, should the water level drop to a low level. This ensures long life and reliability.
Notes:

  1. The fog generated by this device contains microscopic droplets of DI water. AVOID USING IN IMMEDIATE VICINITY OF ELECTRICAL APPLIANCES, WATER SENSITIVE PRODUCTS AND EQUIPMENT.
  2. The fan will operate with no water in the reservoir with the power switch in the ON position. This will aid in drying when the chamber is drained.
  3. Ensure the drain plug is snug tight.
  4. The CRF2 is intended to be used on a flat surface, on its feet, sitting on the floor, table, or a flat trolley cart. Tipping the fogger with water in the reservoir will damage the fogger. DO NOT OVERFILL OR TIP THE CRF2-S FOGGER DURING OPERATION.

CRF2-s Sterilizing Fogger From Applied Physics Inc.

Translate »