Description
Advanced Measurement Technology
The Kanomax Multi-Channel Anemometer PRO – Model 1590 epitomizes precision and responsiveness in airflow measurement technology. Recognized globally for its unparalleled accuracy across the entire air velocity range, including the delicate breeze speed range, this anemometer sets the standard for high-level environmental monitoring. Its capability to perform multipoint measurements on up to 144 channels using the industry’s smallest-level miniature probe ensures detailed and comprehensive data capture.
Enhanced Multi-Channel Anemometer Probes
With 15 types of compatible probes that boast the smallest class size in the industry, the Model 1590 offers exceptional versatility and high heat resistance, allowing for precise measurements even in the most challenging environments. These probes are designed to respond swiftly and accurately, with a micro air velocity limit of 0.01 m/s, facilitating highly accurate readings crucial for critical applications.
Superior Data Handling and Portability
The main unit of the Model 1590 is not only highly portable but also features an enhanced interface, which simplifies the process of simultaneous measurements across multiple points. This efficiency is augmented by the optional analog unit (Model 1592-00), which enables the recording of data on up to 12 channels per unit with selectable current or voltage outputs, facilitating extensive data collection ideal for use with data loggers.
Comprehensive Software and Connectivity
Included with the Model 1590 is a Windows-compatible measurement software, which allows for the simultaneous measurement of air velocity, temperature, and humidity. The software supports real-time graph displays and saves measurement data in a text format that can easily be imported into spreadsheet applications like Excel. Enhanced connectivity options include USB and LAN, with configuration settings adjustable via the main unit’s touch panel or remotely from a PC.
Scalability for Large-Scale Applications
This anemometer’s ability to handle up to 144 channels makes it exceptionally well-suited for large-scale system configurations. Its capability to measure expansive areas efficiently makes it a preferred choice for large-scale space applications, from industrial settings to vehicle testing, where portability and quick setup are essential.
Diverse Industrial Applications
The Kanomax Model 1590 is designed for a variety of demanding applications, including thermal management of automotive ECUs, electronic component heat evaluation, and indoor airflow management for semiconductor manufacturing equipment. It also serves as an indispensable tool for data center thermal management, providing crucial data to optimize the operational efficiency and safety of these facilities.
- 15 types of compatible probes for various applications
- The smallest class probes in the industry
- High heat resistance enables precise measurement even in tough environments
- Large-scale system configuration with up to 144 channels available
- Easily measure in large-scale spaces
- Highly portable main body makes it easy to use in vehicles
- Improved probe response and accuracy, micro air velocity limit of 0.01 m/s
- Support analog output via optional Analog Unit – Model 1592-00
- Windows measurement software simultaneously measures air velocity, temperature, and humidity via the real-time graph display. Measurement data is saved in text format and can be easily imported into table measurement software such as Excel
Main Unit Specifications
| Product | Multi-Channel Anemomaster PRO Main Unit | ||
|---|---|---|---|
| Model | 1590-00 | ||
| Display, Operation | 7-inch color LCD with touch panel | ||
| Communication Function | Data | USB Type-A: For USB memory | |
| Remote Measurement | Modbus (Ethernet, USB Serial) | ||
| Between Units | RS485 (Standard cable) | ||
| Recording Media | Medium | Built-in memory | |
| Format | CSV format | ||
| Recording Capacity | 8GB (One hub unit can measure 1000 sampling times, about 24500 times). | ||
| External Trigger Input | Pin jack terminal Φ2.5 audio jack (Edge detection at start) | ||
| Language | Japanese, English, Chinese | ||
| Power Supply | DC12 to 24V (Select either one of 3 options below)
1) Connection with other unit, 2) AC adaptor (90W), 3) DC power cable |
||
| Power Consumption | Up to 50W | ||
| Operating Environment | 5~40℃, 0~85% RH (No Condensation) | ||
| Storage Environment | -10~60℃, 0~90% RH (No Condensation) |
||
| Dimensions | W220mm × D130mm × H40mm | ||
| Weight | 0.6 kg | ||
| Standard Accessories | AC Adapter (90W), Software (CD), Operation manual, USB cable, Rubber cap | ||
| Warranty | 1 year | ||
Hub Unit Specifications
| Product | Multi-Channel Anemomaster HUB Unit | ||
|---|---|---|---|
| Model | 1591-00 | ||
| Number of Channels | 12ch | ||
| Communication Function | Between Probes | Serial communication (standard cable) | |
| Between Probes | Serial communication (standard cable, connector) | ||
| Between Probes | RS485 (Standard cable) | ||
| Power Supply | DC12 ~ 24V | ||
| Power Consumption | Power supply conforms to the main unit | ||
| Dimensions | W220mm × D130mm × H40mm | ||
| Weight | 0.5 kg | ||
| Standard Accessories | Setup guide, Connecting clips (2pcs) | ||
| Warranty | 1 year | ||
Analog Unit Specifications
| Product | Analog Unit | ||
|---|---|---|---|
| Model | 1592-00 | ||
| Number of Channels | 12 | ||
| Communication Function | Between units | Serial communication {connector} | |
| Analog Output | Voltage output | Range | 0 ~ 5 V |
| Output resistance | 1 kΩ | ||
| Current output | Range | 4 ~20 mA | |
| Load resistance | 250 Ω | ||
| Power Supply | DC12 to 24V (Select either one of 3 options below)
1) Connection with other unit, 2) AC adaptor (90W), 3) DC power cable |
||
| Power Consumption | 10W | ||
| Operating Environment | 5~40℃, 0~85% RH (No Condensation) | ||
| Storage Environment | -10~60℃, 0~90% RH (No Condensation) | ||
| Size | W220mm × D130mm × H40mm | ||
| Weight | 0.5kg | ||
| Standard Accessories | Setup guide, Connecting clips (2pcs), Rubber cap (2pcs), Terminal block (3pcs) | ||
| Warranty | 1 year | ||
Probe Specifications
| Model Number | Measurement Target | Directivity | Air Velocity | Wind Temperature | Humidity | Operating Temperature |
Temperature Compensation Sensor |
||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Measurement Range | Measurement Accuracy | Responsivity | Measurement Range | Measurement Accuracy | Measurement Range | Measurement Accuracy | |||||
| 0972-00 0973-00 |
Wind Speed |
Yes | 0.01~50.0m/s | The larger of ± 2% or ± 0.02 m/s of the displayed value |
1 Second | ー | ー | ー | ー | 0-100℃ | ± 5% of displayed value at 0-100 ℃ |
| 0975-00 | No | 0.01~25.0m/s | 3 Seconds | ||||||||
| 0975-09 0975-10 |
0.01~50.0m/s | ||||||||||
| ± 5% of displayed value at 0-120 ℃ |
|||||||||||
| 0976-03 0976-04 0976-07 |
0.01~30.0m/s | The larger of ± 3% or ± 0.02 m / s of the displayed value |
0-120℃ | ||||||||
| 0976-13 0976-14 0976-17 |
The larger of ± 2% or ± 0.02 m/s of the displayed value |
0-100℃ | ± 5% of displayed value at 0-100 ℃ |
||||||||
| 0976-05 | Air Velocity and Temperature | The larger of ± 3% or ± 0.02 m/s of the displayed value |
0~120℃ | ±0.5% | 0-120℃ | ± 5% of displayed value at 0-120 ℃ |
|||||
| 0976-15 | 0~100℃ | 0-100℃ | ± 5% of displayed value at 0-100 ℃ |
||||||||
| 0975-21 | The larger of ± 2% or ± 0.02 m/s of the displayed value |
||||||||||
| 0975-31 | Air Velocity, Temperature and Humidity |
0.01~25.0m/s | 0~60℃ | 5~95%RH | 5~80% RH:3% RH 80~90% RH: |
||||||




















