MEDICA® R200 Water Purification System for Advanced Laboratory Use

What Is The Medica® R200 System?

The MEDICA® R200 represents a significant advancement in water purification technology designed specifically for clinical laboratory environments. This high-capacity system combines superior purification capabilities with practical design features to meet the demanding requirements of modern diagnostic facilities.

As laboratory operations expand and automation becomes more prevalent, reliable access to high-purity water has become a critical resource for ensuring accurate test results and efficient operations.

How does the R200 function in a laboratory setting?

The MEDICA® R200 serves as a central water purification hub in clinical laboratories, drawing in feed water and processing it through multiple purification stages including pre-treatment filtration, reverse osmosis, and UV sterilization to produce CLRW standard water.

 It maintains a consistent flow rate of 18-21 liters per minute through its integrated 350-liter reservoir, enabling simultaneous supply to multiple diagnostic analyzers via a distribution loop system that can extend up to 200 meters throughout a facility.

The system continuously recirculates water through its purification pathway when not in active use, preventing bacterial growth and maintaining consistent quality standards (<10 CFU/ml bacterial content and <30 ppb organics).

For reliability in critical settings, the R200 incorporates an emergency bypass loop ensuring uninterrupted water supply during maintenance, while its advanced control system continuously monitors water quality parameters and provides real-time status updates through an intuitive graphical interface.

This comprehensive functionality makes the R200 particularly valuable in high-volume clinical settings where water purity directly impacts diagnostic accuracy and laboratory efficiency.

What makes the medica® R200 unique compared to other systems?

The MEDICA® R200 is unique compared to other water purification systems due to its exceptional high-flow capacity, capable of delivering up to 21 liters per minute of CLRW standard water, enabling it to support multiple clinical analyzers simultaneously.

Its integrated 350-liter wrap-around reservoir design enhances space efficiency, while the emergency bypass loop ensures a continuous water supply even during critical laboratory operations. The system's distribution loop capability allows it to extend up to 200 meters across multiple laboratories and different floors, simplifying centralized water purification.

With low running and consumable costs, this system is economically efficient, while its single system design significantly simplifies installation and maintenance.

Its superior water quality specifications (<10 CFU/ml bacteria and <30 ppb organics) make it suitable for the most sensitive diagnostic procedures, and the comprehensive monitoring and control interface provides laboratory staff with real-time quality assurance. 

This combination of features makes the MEDICA® R200 the most reliable and versatile water purification solution in high-volume clinical settings.

MEDICA® R200 System at a Glance: Key Capabilities and Benefits

Capability Technical Details Benefits
High-Volume Output 18-21 liters per minute flow rate
200 liters per hour capacity
Supports multiple analyzers simultaneously
 Eliminates wait times for water availability
Premium Water Quality CLRW/CLSI Type 1 standard
<10 CFU/ml bacteria
<30 ppb organics
>10 MΩ.cm resistivity
Ensures reliable diagnostic results
Prevents contamination-related errors
Meets stringent clinical laboratory requirements
Integrated Storage Solution 350-liter wrap-around reservoir
Continuous recirculation technology
Space-efficient design
Maintains water quality during storage
Provides buffer during peak demand periods
Extensive Distribution 200-meter pipeline support
Multi-floor/multi-laboratory capability
Centralizes water purification
Reduces the need for multiple systems
Simplifies maintenance management
Operational Reliability Emergency bypass loop
Continuous system monitoring
Automated sanitization
Ensures uninterrupted laboratory operations
Minimizes downtime during maintenance
Reduces risk of bacterial contamination
Economic Efficiency Extended consumable life (RO module: 24-36 months)
Energy-efficient recirculation
Low maintenance design
Reduces operational costs
Minimizes service interruptions
Optimizes total cost of ownership
User-Friendly Interface Graphical quality display
Intuitive control system
Adjustable alarm setpoints
Simplifies daily operation
Provides clear quality assurance
Minimizes training requirements
Installation Flexibility Compact vertical design
Plug-and-play analyzer connections
Modular components
Maximizes available laboratory space
Integrates easily with existing setups
Simplifies future expansions

Meeting Critical Clinical Water Standards

Clinical laboratories require water that meets specific quality parameters to ensure reliable diagnostic results. The MEDICA® R200 system consistently delivers Clinical Laboratory Reagent Water (CLRW) standard water—formerly known as CLSI Type 1—with impressive specifications:

  • Inorganics resistance: >10 MΩ.cm
  • Organic (TOC) levels: <30 ppb
  • Bacterial content: <10 CFU/ml
  • Particle filtration: 0.2 μm filter
  • Silica levels: <0.05 mg/l

These specifications ensure that water quality doesn't compromise analytical results or interfere with sensitive diagnostic procedures.

High-Volume Capacity for Multi-Analyzer Environments

Exceptional Flow Rates

One of the MEDICA® R200's standout features is its impressive flow capacity:

  • Maximum delivery flow rate: 21 liters per minute
  • Minimum delivery flow rate: 18 liters per minute
  • Daily capacity: Up to 200 liters per hour 

This high-volume capability allows the system to support multiple diagnostic analyzers simultaneously, making it ideal for busy hospital laboratories and reference labs with high throughput requirements.

Distribution Loop Flexibility

The MEDICA® R200 is engineered to:

  • Support multiple analyzers across several laboratories via a distribution loop system
  • Maintain consistent water quality throughout extended pipeline networks
  • Provide reliable service across different floors of a facility.

Smart Design Features for Laboratory Environments

Space-Efficient Configuration

Despite its high capacity, the MEDICA® R200 maintains a relatively compact footprint thanks to its innovative design:

  • Integrated 350-liter wrap-around reservoir that efficiently uses vertical space.
  • Single system design that simplifies installation and project planning. 
  • Loop installation options that can extend up to 200 meters from the main unit.

Reliability and Redundancy

Laboratory operations depend on continuous water availability. The MEDICA® R200 incorporates several features to ensure reliable operation:

  • Emergency bypass loop that maintains compliant water supply during maintenance or emergencies
  • Award-winning design integrating high-output purification, storage, and distribution components 
  • Recirculation capabilities that preserve water quality during periods of low usage.

Key Features of the medica® R200

  • High-speed water supply up to 21 liters per minute - The ability to deliver CLRW standard water at 21L/min, feeding multiple analyzers simultaneously.
  • 350-liter built-in reservoir - An integrated wrap-around tank that saves space and guarantees 24/7 water availability.
  • Emergency bypass loop system - Ensures compliance with water supply to laboratories even during maintenance or breakdowns.
  • 200-meter pipeline support - Capability to distribute water from a single system across multiple floors and laboratories.
  • CLSI Type 1 standard purity - Super-clean water with <10 CFU/ml bacteria, <30 ppb organics, and >10 MΩ-cm resistivity.
  • Low-cost operation - The long lifespan of RO filters and UV lamps (24-36 months) reduces operating costs.
  • Auto-sanitization and monitoring - Real-time water quality checks and alerts that minimize the need for manual supervision.
  • Plug-and-play installation - Compatibility for direct connection with any lab analyzer and easy setup.

Performance and Efficiency of the medica® R200

The MEDICA® R200 delivers exceptional performance with its impressive 21 liters per minute flow rate, consistently meeting CLRW standards with <10 CFU/ml bacterial content and <30 ppb organics—making it ideal for high-volume clinical settings.

Its integrated 350-liter reservoir and distribution loop system efficiently service multiple analyzers across different laboratory locations, while the emergency bypass feature ensures uninterrupted operation during maintenance periods.

The system's energy-efficient design and extended consumable lifecycles (with RO modules lasting 24-36 months) significantly reduce running costs compared to conventional systems.

With continuous recirculation technology that prevents bacterial growth during idle periods and real-time monitoring capabilities, the R200 maintains water quality integrity while minimizing labor requirements, providing laboratories with a reliable, economical, and high-performance water purification solution.

What is the water output capacity of the medica® R200?

The MEDICA® R200 delivers exceptional water purification capacity with output ranging from 18 to 21 liters per minute of CLRW standard water, making it ideal for high-volume clinical laboratory environments.

Its integrated 350-liter reservoir ensures continuous supply while maintaining critical quality parameters (<10 CFU/ml bacterial content, <30 ppb organics). The system can support multiple diagnostic analyzers simultaneously through its distribution loop capability that extends up to 200 meters throughout a facility.

This impressive output capacity combined with consistent quality delivery positions the MEDICA® R200 as the optimal solution for laboratories requiring reliable, high-volume purified water for sensitive diagnostic procedures.

How does the system provide 21 liters per minute of CLRW standard water?

The MEDICA® R200 achieves its impressive 21 liters per minute flow rate through a sophisticated multi-stage purification process that includes high-capacity pre-filtration, industrial-grade reverse osmosis membranes, and advanced UV sterilization technology.

Its integrated 350-liter reservoir serves as both storage and pressure stabilization, allowing consistent high-volume output while maintaining CLRW quality standards. The system employs continuous recirculation technology that constantly moves water through the purification pathway even during periods of low demand, preventing bacterial proliferation and ensuring immediate availability of compliant water.

This advanced engineering is complemented by precision flow control systems that regulate pressure and volume to deliver 18-21 L/min of purified water that consistently meets or exceeds all clinical laboratory reagent water requirements.

Technical Specifications and Requirements

Consumable Components

The MEDICA® R200 utilizes several replaceable components to maintain water quality:

  • Reverse Osmosis Module (LC161): 24-36 month life expectancy
  • Ultra-micron filter (LC160): 14 month life expectancy
  • Pre-treatment filter (LC159): 6-month life expectancy
  • UV Light (LC158): 12-18 month life expectancy
  • Composite Vent Filter (LC156): 12-month life expectancy.

Control System

The system features advanced control capabilities including:

    • Continuous graphical quality display
    • Intuitive icon-based interface
    • Adjustable alarm setpoints
    • Automated sanitization protocols 
    • Remote monitoring options

Compact Design and Space Saving

1. The MEDICA® R200's compact design utilizes minimal floor space in laboratories, making integration easy. 

2. Its innovative vertical reservoir design optimally uses the available space and enhances overall efficiency. 

3. By seamlessly integrating with existing setups, it supports multiple analyzers without demanding additional space. 

4. This compact configuration not only simplifies installation but also streamlines maintenance and operation.

What advantages does the compact design of the medica® R200 offer?

1. ts vertical integrated reservoir design maximizes available space and reduces the need for separate utility rooms.

2. The system can be easily integrated into existing laboratory setups without disrupting workflow.

3. The compact configuration simplifies maintenance and operational access, thereby enhancing service efficiency.

How can the R200 system be integrated into existing laboratory setups?

1. The system comes with flexible connection points and modular components that can seamlessly connect with existing water lines and analyzers.

2. Its compact footprint allows it to fit under or beside lab benches or countertops, ensuring space optimization.

3. Through its distribution loop capability, the system can extend up to 200 meters in the pipeline, allowing supply to multiple analyzers and multiple laboratories from a single system.

4. The emergency bypass loop integration ensures that a continuous water supply is maintained during critical operations without any disruption.

5. The system can be easily integrated with existing Laboratory Information Management Systems (LIMS) and control interfaces for centralized monitoring and management.

6. The installation process includes full service and validation support to ensure smooth integration and compliance with all regulatory standards.

Economical Operation and Maintenance

Cost-Effective Design

The MEDICA® R200 is designed to minimize both initial and ongoing costs:

  • Low running and consumable costs compared to traditional water purification systems
  • Integrated design that reduces installation complexity and associated expenses
  • Energy-efficient operation through smart recirculation programming.

Simplified Maintenance

The system features:

  • Accessible consumable components with clear replacement schedules
  • Intuitive control interface with programmable maintenance reminders
  • Comprehensive monitoring of system parameters.

Conclusion

The MEDICA® R200 Water Purification System is an advanced solution designed for laboratories requiring high-purity water for critical applications. With its cutting-edge filtration technology, consistent output, and user-friendly design, it ensures reliability and efficiency in laboratory operations.

Whether used for clinical diagnostics, research, or analytical procedures, the MEDICA® R200 stands out as a dependable choice for laboratories that demand precision and quality.

FAQs

1. What is the primary function of the MEDICA® R200 Water Purification System?
The MEDICA® R200 provides high-purity water suitable for clinical diagnostics, research laboratories, and analytical applications.


2. What is the water production capacity of the MEDICA® R200?
It can deliver up to 200 liters per hour of purified water, ensuring a steady supply for laboratory needs.


3. Does the MEDICA® R200 require frequent maintenance?
The system is designed for low maintenance, featuring automated monitoring and easy filter replacement to minimize downtime.


4. What makes the MEDICA® R200 different from other water purification systems?
It offers a high flow rate, advanced filtration, real-time monitoring, and compliance with laboratory standards, making it ideal for high-demand environments.


5. Is the MEDICA® R200 easy to install and operate?
Yes, the system features a user-friendly interface and a compact design, making installation and daily operation simple and efficient.

Back to blog