Lab Water Problems? Modulab – The Ultimate Solution for Consistent, Pure Water!

Introducing The MODULAB® High Flow Water Purification System

The success of lab experiments depends on water quality. If the water is impure, not only can your results become inaccurate, but sensitive equipment can also be damaged.
The Modulab® High Flow Water Purification System is a revolutionary solution that provides high-purity water for laboratories without any compromise.

What Makes MODULAB® Different?

  • High Flow & High Purity: MODULAB® combines both things – high flow and ultra-pure water.

  • Innovative Design: Compared to traditional systems, MODULAB® maintains a balance between flow rate and purity.
  • No Compromise: You don’t have to sacrifice either flow rate or purity

How does the system deliver up to 14 liters per minute?

Feature/Component Function Benefit
Powerful Pump Supplies water at a high flow rate More water is delivered in less time
Wide Tubing Ensures smooth and fast water flow Reduces flow blockage
Advanced Filtration Maintains flow even during filtration Clean water without losing flow rate
Automated Control Adjusts flow as needed Consistent required rate at all times
Large Storage Tank Stores more water at once No supply interruptions

Key Features and Technical Specifications

Advanced Purification Technology

The MODULAB® system employs a multi-stage purification process that effectively removes:
  • Particulates and suspended solids
  • Dissolved inorganic compounds
  • Organic contaminants
  • Microorganisms and pyrogens
  • Dissolved gases.

Performance Specifications

Parameter
Specification
Maximum Flow Rate
14 liters per minute
Water Quality
Type 1 / Ultra-pure
Resistivity
>18.2 MΩ·cm
TOC Levels
<5 ppb
Bacterial Content
<0.1 CFU/ml
Particulates
<1 per ml

Why Choose MODULAB® for Your Laboratory

The MODULAB® High Flow Water Purification System represents an investment in laboratory quality and efficiency.

Providing consistent, high-purity water at exceptional flow rates eliminates one of the most common sources of experimental variability.

For laboratories facing water purity challenges, the MODULAB® system offers:
  • Reliability: Consistent performance every day.
  • Efficiency: High flow rates mean no bottlenecks, work gets done faster.
  • Compliance: All regulatory requirements are met.

Why is Water Purification Important in a Lab Setting?

In lab experiments, water quality directly affects your results. If the water is contaminated, not only can your results be incorrect, but sensitive lab equipment can also be damaged.

 Benefits of using a high-flow water purification system

  1. Fast Flow Rate: More water is available quickly, perfect for high-demand labs.
  2. Ultra-Pure Water: Type 1 water, which is ideal for sensitive experiments.
  3. Consistent Quality: High-quality water at all times, supporting the accuracy of your experiments.
  4. Advanced Filtration: Contamination is removed through UV sterilization and carbon filters.

Modular Design Advantages

The system's modular architecture provides several key benefits:

  1. Scalability: Add or remove components based on changing laboratory needs
  2. Redundancy: Critical components have backup systems to prevent downtime
  3. Serviceability: Individual modules can be maintained without shutting down the entire system
  4. Upgradability: New purification technologies can be integrated without replacing the entire system.

Comparison with Other Systems

MODULAB® vs. MEDICA®-S and -R Systems

While the MODULAB® system is designed for high-volume laboratory needs, Applied Physics Corporation also offers the MEDICA®-S and -R systems for more specialized applications:
Feature
MODULAB®
MEDICA®-S/R
Flow Rate
Up to 14 L/min
7-15 L/hr with 1.8 L/min peak
Best For
Multiple users/applications
Single analyzer use
Design
Modular, expandable
Compact, dedicated
Water Grade
Type 1 / Ultra-pure
CLRW grade
The MEDICA® systems provide an ideal solution for clinical analyzers with lower volume requirements, offering economical operation while maintaining necessary purity levels.

Applications Across Laboratory Disciplines

Clinical Diagnostics

In clinical settings, the MODULAB® system ensures:
  • Consistent analyzer performance
  • Reliable diagnostic results
  • Compliance with laboratory regulations
  • Reduced contamination risks.

Pharmaceutical Research

Pharmaceutical laboratories benefit from:

  • Ultra-pure water for drug formulation
  • Consistent quality for validation studies
  • High flow rates for production-scale research
  • Compliance with industry standards.

Academic Research

University and research institutions can:
  • Support multiple diverse research projects simultaneously
  • Achieve reproducible experimental conditions
  • Eliminate water purity as a variable in experiments
  • Reduce cross-contamination between studies.

Industrial Applications

The system's capabilities extend to industrial settings:
  • Quality control laboratories
  • Manufacturing processes requiring pure water
  • Product development and testing facilities
  • Environmental monitoring operations.

Installation and Maintenance Considerations

System Requirements

To operate efficiently, the MODULAB® system requires:
  • Suitable feed water quality (municipal tap water is typically sufficient)
  • Appropriate drainage facilities
  • Standard electrical connections
  • Adequate space for installation and maintenance access.

Recommended Maintenance Schedule

For optimal performance:
  • Daily: System status check
  • Weekly: Sanitization procedures
  • Monthly: Filter inspection and replacement (as needed)
  • Quarterly: Comprehensive system evaluation
  • Annually: Professional service inspection

Conclusion

If your laboratory is constantly facing water-related issues—whether it's contamination, inconsistent supply, or unreliable purification—Modulab is your go-to solution.

With cutting-edge technology, consistent water quality, and dependable support, Modulab ensures your experiments never stop due to water problems.
Modulab Where Science Begins and Water Problems End.

FAQs

1. What types of water systems does Modulab provide?
Modulab offers a full range of lab-grade water purification systems, including Reverse Osmosis (RO), Deionized (DI), and Ultrapure Water systems—ideal for research and analytical labs.

2. Are Modulab systems energy-efficient?
Absolutely. Our systems are designed using advanced technology that saves both energy and water, without compromising performance.

3. What if I face a problem with the system?
We offer 24/7 customer support via phone and online. Our rapid-response team is available for on-site service within 24 hours.

4. Does Modulab offer installation and maintenance services?
Yes, we provide complete installation, routine maintenance, and annual service contracts to keep your system performing at its best.

5. Can Modulab water systems be customized to fit specific lab requirements?
Yes, Modulab offers customizable water purification solutions tailored to your lab's unique needs, whether it’s for a small laboratory or a large research facility. Our team works with you to configure the best system for your workflow