Vertical Laminar Flow Cabinet (BKCB-V500): Features, Specifications & Applications, Benefits

In high-precision laboratory environments, maintaining sterile conditions is very important. The Vertical Laminar Flow Cabinet (BKCB-V500) is an advanced solution that controls airborne contamination in sensitive workspaces. This cabinet is designed for cleanroom performance and is essential for applications requiring particle-free air and product protection.

This article provides a comprehensive overview of the BKCB-V500, including its features, technical specifications, real-world applications, and unique benefits. Whether you are a lab technician, researcher, buyer, or cleanroom designer, this guide will help you understand why the BKCB-V500 is a reliable and efficient choice.

What Is a Vertical Laminar Flow Cabinet?

A vertical laminar flow cabinet is a clean bench designed to direct filtered air downward in a vertical stream. This air passes through a HEPA filter, ensuring the workspace remains free of dust, microbes, and other airborne contaminants.

Lab equipment with a touchscreen interface for controlled environment work, ensuring safety and precision in experiments.

Compared to horizontal cabinets, vertical flow cabinets provide better protection against cross-contamination and are commonly used in laboratories, hospitals, pharmaceutical research facilities, and electronics manufacturing units.

Key Features

High-Efficiency HEPA Filtration

The cabinet is equipped with a HEPA H14 filter, which provides an efficiency of≥99.995% for particles as small as 0.3 microns. This ensures a clean and safe workspace by removing most airborne contaminants.

Vertical Laminar Airflow

The vertical airflow system pushes filtered air from the top downward, reducing the risk of contamination from the user or the surrounding environment.

Sterile laminar flow hood used in labs to provide a contaminant-free environment by directing filtered air over the work surface.

Touchscreen Control Panel

The 7-inch color display shows real-time data, including:

  • Air velocity
  • Filter usage time
  • Temperature and humidity
  • System diagnostics
  • Clock and scheduling options.

UV Germicidal Lamp

The cabinet is fitted with dual UV lamps that sterilize the area when not in use. It supports programmable disinfection cycles with safety interlocks.

Tempered Glass Construction

The front and side panels are made of 5 mm-thick tempered glass, offering both good visibility and physical safety during use.

Low Noise and Vibration

Noise levels stay below 65 dB(A), making it ideal for quiet laboratory environments. Vibration levels are also minimal, enhancing operational stability.

Technical Specifications

Here is a table summarizing the technical details of the BKCB-V500 model:

Parameter Specification
External Dimensions (mm) 550 × 460 × 700
Internal Workspace Dimensions 480 × 340 × 370
Weight (Net / Gross) 45 kg / 57 kg
Power Supply 220V ±10%, 50Hz (110V optional)
Rated Power Consumption 620 VA
Air Velocity 0.2 to 0.45 m/s
Noise Level ≤ 65 dB(A)
Vibration Level ≤ 5 µm
Lighting ≥ 300 lux
Cleanliness Level ISO Class 5 / Class 100
Safety Window Height 200 mm (adjustable up to ~260 mm)
UV Disinfection Lamp 2 × UV Lamps
LED Lighting 1 × LED Lamp
Filter Type HEPA H14 with pre-filter
Material (Cabinet Surface) 304 Stainless Steel (work zone)
Display System 7" LCD Touchscreen

Applications

The BKCB-V500 is designed for various industries and types of labs. Its compact size and cleanroom-grade protection make it useful and efficient for different purposes.

Four images showing vertical laminar flow cabinets used in different lab settings. Top left: a hospital lab technician working with samples. Top right: a pharmaceutical lab worker handling materials inside the cabinet. Bottom left: a person in protective gear working in an electronics cleanroom. Bottom right: a microbiology lab technician using the cabinet for sterile work. Each cabinet has a digital display and safety warnings.

1. Clinical Laboratories

Used for microbiological testing, blood sample analysis, and tissue culture procedures.

2. Pharmaceutical Industry

Provides a contamination-free workspace for weighing, formulation, and small-scale batch production.

3. Electronics Manufacturing

Ensures dust-free assembly of sensitive components like circuit boards and sensors.

4. Research & Development

Ideal for molecular biology, biotechnology, and analytical chemistry work.

5. Education and Training Labs

Used in universities and training centers for safe hands-on laboratory practice.

Advantages of Using

Enhanced Product Protection

The consistent vertical laminar airflow ensures that samples and processes are protected from particulate contamination.

Ease of Operation

Its intuitive touchscreen interface, adjustable windows, and ergonomic design make it easy to use for both new and experienced personnel.

Scientist wearing PPE working in a biosafety cabinet, handling test tubes for lab research.

Energy Efficiency

The unit consumes minimal power, making it cost-effective and environmentally friendly, especially for continuous lab use.

High Durability

The powder-coated steel body and stainless-steel work surface provide long-term resistance to corrosion and chemical exposure.

Comprehensive Safety Features

With front window interlocks, overpressure alerts, and UV safety systems, the cabinet ensures maximum protection for both users and the environment.

Where to Buy the BKCB-V500 Cabinet

If you want to purchase the Vertical Laminar Flow Cabinet (BKCB-V500), you can place your order directly. This model is available on the official website, where you can easily make a secure and verified purchase.

When you order directly:

  • You get a guarantee of a genuine product
  • Fast shipping options are available
  • Warranty and installation support are ensured.

Besides the website, you can also buy this cabinet through authorized laboratory equipment distributors. However, it is recommended to order directly to receive full after-sales support.

Before placing your order, please make sure to confirm:

  • Product warranty period
  • Delivery timeline
  • Availability of installation or setup guidance
  • Post-purchase service support.

If you need a quotation or assistance, please contact the sales team. They are always ready to recommend the best solution for your facility.

Maintenance and Care

Maintaining the BKCB-V500 is straightforward and cost-effective.

  • Filter Replacement: HEPA filters should be inspected every 6–12 months and replaced as needed.
  • Surface Cleaning: Clean stainless steel surfaces with ethanol-based disinfectants after every shift.
  • UV Lamp Check: Replace UV lamps every 1000–2000 hours of operation to maintain effective sterilization.
  • Software Updates: Keep firmware and digital monitoring tools updated for improved diagnostics and control.

Conclusion

The BKCB-V500 Vertical Laminar Flow Cabinet is an excellent solution for labs and clean environments where product protection and air purity are very important. It combines advanced filtration, modern controls, and safety mechanisms into a compact and efficient design. Whether you are setting up a new facility or upgrading an old one, the BKCB-V500 offers unmatched value in easily maintaining ISO Class 5 cleanliness with long-term reliability.

FAQs

What is the primary purpose of a vertical laminar flow cabinet?
It provides a sterile, particle-free environment using filtered vertical airflow to protect samples or materials from contamination.

Is the BKCB-V500 suitable for medical labs?
Yes. Its ISO Class 5 rating and UV disinfection make it ideal for medical, pharmaceutical, and research laboratories.

How often should the HEPA filter be replaced?
Typically, every 6 to 12 months, depending on usage and environmental conditions.

Can I install it in a small lab?
Yes. The compact design and low noise level make it perfect for space-restricted lab environments.

Does it require professional installation?
Not necessarily. It arrives pre-assembled and can be set up by lab personnel, but calibration by a certified technician is recommended.

Back to blog