Applied Physics · Precision technologies since 1992
Request Quote

What Is The Medica® R200 System?

The MEDICA® R200 represents a significant advancement in water purification technology designed specifically for clinical laboratory environments. This high-capacity system combines superior purification capabilities with practical design features to meet the demanding requirements of modern diagnostic facilities.

As laboratory operations expand and automation becomes more prevalent, reliable access to high-purity water has become a critical resource for ensuring accurate test results and efficient operations.

How does the R200 function in a laboratory setting?

The MEDICA® R200 serves as a central water purification hub in clinical laboratories, drawing in feed water and processing it through multiple purification stages including pre-treatment filtration, reverse osmosis, and UV sterilization to produce CLRW standard water.

 It maintains a consistent flow rate of 18-21 liters per minute through its integrated 350-liter reservoir, enabling simultaneous supply to multiple diagnostic analyzers via a distribution loop system that can extend up to 200 meters throughout a facility.

The system continuously recirculates water through its purification pathway when not in active use, preventing bacterial growth and maintaining consistent quality standards (<10 CFU/ml bacterial content and <30 ppb organics).

For reliability in critical settings, the R200 incorporates an emergency bypass loop ensuring uninterrupted water supply during maintenance, while its advanced control system continuously monitors water quality parameters and provides real-time status updates through an intuitive graphical interface.

This comprehensive functionality makes the R200 particularly valuable in high-volume clinical settings where water purity directly impacts diagnostic accuracy and laboratory efficiency.

What makes the medica® R200 unique compared to other systems?

The MEDICA® R200 is unique compared to other water purification systems due to its exceptional high-flow capacity, capable of delivering up to 21 liters per minute of CLRW standard water, enabling it to support multiple clinical analyzers simultaneously.

Its integrated 350-liter wrap-around reservoir design enhances space efficiency, while the emergency bypass loop ensures a continuous water supply even during critical laboratory operations. The system’s distribution loop capability allows it to extend up to 200 meters across multiple laboratories and different floors, simplifying centralized water purification.

With low running and consumable costs, this system is economically efficient, while its single system design significantly simplifies installation and maintenance.

Its superior water quality specifications (<10 CFU/ml bacteria and <30 ppb organics) make it suitable for the most sensitive diagnostic procedures, and the comprehensive monitoring and control interface provides laboratory staff with real-time quality assurance. 

This combination of features makes the MEDICA® R200 the most reliable and versatile water purification solution in high-volume clinical settings.

MEDICA® R200 System at a Glance: Key Capabilities and Benefits

Capability Technical Details Benefits
High-Volume Output 18-21 liters per minute flow rate
200 liters per hour capacity
Supports multiple analyzers simultaneously
 Eliminates wait times for water availability
Premium Water Quality CLRW/CLSI Type 1 standard
<10 CFU/ml bacteria
<30 ppb organics
>10 MΩ.cm resistivity
Ensures reliable diagnostic results
Prevents contamination-related errors
Meets stringent clinical laboratory requirements
Integrated Storage Solution 350-liter wrap-around reservoir
Continuous recirculation technology
Space-efficient design
Maintains water quality during storage
Provides buffer during peak demand periods
Extensive Distribution 200-meter pipeline support
Multi-floor/multi-laboratory capability
Centralizes water purification
Reduces the need for multiple systems
Simplifies maintenance management
Operational Reliability Emergency bypass loop
Continuous system monitoring
Automated sanitization
Ensures uninterrupted laboratory operations
Minimizes downtime during maintenance
Reduces risk of bacterial contamination
Economic Efficiency Extended consumable life (RO module: 24-36 months)
Energy-efficient recirculation
Low maintenance design
Reduces operational costs
Minimizes service interruptions
Optimizes total cost of ownership
User-Friendly Interface Graphical quality display
Intuitive control system
Adjustable alarm setpoints
Simplifies daily operation
Provides clear quality assurance
Minimizes training requirements
Installation Flexibility Compact vertical design
Plug-and-play analyzer connections
Modular components
Maximizes available laboratory space
Integrates easily with existing setups
Simplifies future expansions

Meeting Critical Clinical Water Standards

Clinical laboratories require water that meets specific quality parameters to ensure reliable diagnostic results. The MEDICA® R200 system consistently delivers Clinical Laboratory Reagent Water (CLRW) standard water—formerly known as CLSI Type 1—with impressive specifications:

These specifications ensure that water quality doesn’t compromise analytical results or interfere with sensitive diagnostic procedures.

High-Volume Capacity for Multi-Analyzer Environments

Exceptional Flow Rates

One of the MEDICA® R200’s standout features is its impressive flow capacity:

This high-volume capability allows the system to support multiple diagnostic analyzers simultaneously, making it ideal for busy hospital laboratories and reference labs with high throughput requirements.

Distribution Loop Flexibility

The MEDICA® R200 is engineered to:

Smart Design Features for Laboratory Environments

Space-Efficient Configuration

Despite its high capacity, the MEDICA® R200 maintains a relatively compact footprint thanks to its innovative design:

Reliability and Redundancy

Laboratory operations depend on continuous water availability. The MEDICA® R200 incorporates several features to ensure reliable operation:

Key Features of the medica® R200

Performance and Efficiency of the medica® R200

The MEDICA® R200 delivers exceptional performance with its impressive 21 liters per minute flow rate, consistently meeting CLRW standards with <10 CFU/ml bacterial content and <30 ppb organics—making it ideal for high-volume clinical settings.

Its integrated 350-liter reservoir and distribution loop system efficiently service multiple analyzers across different laboratory locations, while the emergency bypass feature ensures uninterrupted operation during maintenance periods.

The system’s energy-efficient design and extended consumable lifecycles (with RO modules lasting 24-36 months) significantly reduce running costs compared to conventional systems.

With continuous recirculation technology that prevents bacterial growth during idle periods and real-time monitoring capabilities, the R200 maintains water quality integrity while minimizing labor requirements, providing laboratories with a reliable, economical, and high-performance water purification solution.

What is the water output capacity of the medica® R200?

The MEDICA® R200 delivers exceptional water purification capacity with output ranging from 18 to 21 liters per minute of CLRW standard water, making it ideal for high-volume clinical laboratory environments.

Its integrated 350-liter reservoir ensures continuous supply while maintaining critical quality parameters (<10 CFU/ml bacterial content, <30 ppb organics). The system can support multiple diagnostic analyzers simultaneously through its distribution loop capability that extends up to 200 meters throughout a facility.

This impressive output capacity combined with consistent quality delivery positions the MEDICA® R200 as the optimal solution for laboratories requiring reliable, high-volume purified water for sensitive diagnostic procedures.

How does the system provide 21 liters per minute of CLRW standard water?

The MEDICA® R200 achieves its impressive 21 liters per minute flow rate through a sophisticated multi-stage purification process that includes high-capacity pre-filtration, industrial-grade reverse osmosis membranes, and advanced UV sterilization technology.

Its integrated 350-liter reservoir serves as both storage and pressure stabilization, allowing consistent high-volume output while maintaining CLRW quality standards. The system employs continuous recirculation technology that constantly moves water through the purification pathway even during periods of low demand, preventing bacterial proliferation and ensuring immediate availability of compliant water.

This advanced engineering is complemented by precision flow control systems that regulate pressure and volume to deliver 18-21 L/min of purified water that consistently meets or exceeds all clinical laboratory reagent water requirements.

Technical Specifications and Requirements

Consumable Components

The MEDICA® R200 utilizes several replaceable components to maintain water quality:

You were not leaving your cart just like that, right?

You were not leaving your cart just like that, right?

Enter your details below to save your shopping cart for later. And, who knows, maybe we will even send you a sweet discount code :)

Want to receive personalized offers?

Allow notifications to get real-time updates about your shopping cart and who knows, you may even receive a sweet discount code 😊

Maybe later