The MEDICA® R200 represents a significant advancement in water purification technology designed specifically for clinical laboratory environments. This high-capacity system combines superior purification capabilities with practical design features to meet the demanding requirements of modern diagnostic facilities.
As laboratory operations expand and automation becomes more prevalent, reliable access to high-purity water has become a critical resource for ensuring accurate test results and efficient operations.
The MEDICA® R200 serves as a central water purification hub in clinical laboratories, drawing in feed water and processing it through multiple purification stages including pre-treatment filtration, reverse osmosis, and UV sterilization to produce CLRW standard water.
It maintains a consistent flow rate of 18-21 liters per minute through its integrated 350-liter reservoir, enabling simultaneous supply to multiple diagnostic analyzers via a distribution loop system that can extend up to 200 meters throughout a facility.
The system continuously recirculates water through its purification pathway when not in active use, preventing bacterial growth and maintaining consistent quality standards (<10 CFU/ml bacterial content and <30 ppb organics).
For reliability in critical settings, the R200 incorporates an emergency bypass loop ensuring uninterrupted water supply during maintenance, while its advanced control system continuously monitors water quality parameters and provides real-time status updates through an intuitive graphical interface.
This comprehensive functionality makes the R200 particularly valuable in high-volume clinical settings where water purity directly impacts diagnostic accuracy and laboratory efficiency.
The MEDICA® R200 is unique compared to other water purification systems due to its exceptional high-flow capacity, capable of delivering up to 21 liters per minute of CLRW standard water, enabling it to support multiple clinical analyzers simultaneously.
Its integrated 350-liter wrap-around reservoir design enhances space efficiency, while the emergency bypass loop ensures a continuous water supply even during critical laboratory operations. The system’s distribution loop capability allows it to extend up to 200 meters across multiple laboratories and different floors, simplifying centralized water purification.
With low running and consumable costs, this system is economically efficient, while its single system design significantly simplifies installation and maintenance.
Its superior water quality specifications (<10 CFU/ml bacteria and <30 ppb organics) make it suitable for the most sensitive diagnostic procedures, and the comprehensive monitoring and control interface provides laboratory staff with real-time quality assurance.
This combination of features makes the MEDICA® R200 the most reliable and versatile water purification solution in high-volume clinical settings.
| Capability | Technical Details | Benefits |
|---|---|---|
| High-Volume Output | 18-21 liters per minute flow rate 200 liters per hour capacity | Supports multiple analyzers simultaneously Eliminates wait times for water availability |
| Premium Water Quality | CLRW/CLSI Type 1 standard <10 CFU/ml bacteria <30 ppb organics >10 MΩ.cm resistivity | Ensures reliable diagnostic results Prevents contamination-related errors Meets stringent clinical laboratory requirements |
| Integrated Storage Solution | 350-liter wrap-around reservoir Continuous recirculation technology | Space-efficient design Maintains water quality during storage Provides buffer during peak demand periods |
| Extensive Distribution | 200-meter pipeline support Multi-floor/multi-laboratory capability | Centralizes water purification Reduces the need for multiple systems Simplifies maintenance management |
| Operational Reliability | Emergency bypass loop Continuous system monitoring Automated sanitization | Ensures uninterrupted laboratory operations Minimizes downtime during maintenance Reduces risk of bacterial contamination |
| Economic Efficiency | Extended consumable life (RO module: 24-36 months) Energy-efficient recirculation Low maintenance design | Reduces operational costs Minimizes service interruptions Optimizes total cost of ownership |
| User-Friendly Interface | Graphical quality display Intuitive control system Adjustable alarm setpoints | Simplifies daily operation Provides clear quality assurance Minimizes training requirements |
| Installation Flexibility | Compact vertical design Plug-and-play analyzer connections Modular components | Maximizes available laboratory space Integrates easily with existing setups Simplifies future expansions |
Clinical laboratories require water that meets specific quality parameters to ensure reliable diagnostic results. The MEDICA® R200 system consistently delivers Clinical Laboratory Reagent Water (CLRW) standard water—formerly known as CLSI Type 1—with impressive specifications:
These specifications ensure that water quality doesn’t compromise analytical results or interfere with sensitive diagnostic procedures.
One of the MEDICA® R200’s standout features is its impressive flow capacity:
This high-volume capability allows the system to support multiple diagnostic analyzers simultaneously, making it ideal for busy hospital laboratories and reference labs with high throughput requirements.
The MEDICA® R200 is engineered to:
Despite its high capacity, the MEDICA® R200 maintains a relatively compact footprint thanks to its innovative design:
Laboratory operations depend on continuous water availability. The MEDICA® R200 incorporates several features to ensure reliable operation:
The MEDICA® R200 delivers exceptional performance with its impressive 21 liters per minute flow rate, consistently meeting CLRW standards with <10 CFU/ml bacterial content and <30 ppb organics—making it ideal for high-volume clinical settings.
Its integrated 350-liter reservoir and distribution loop system efficiently service multiple analyzers across different laboratory locations, while the emergency bypass feature ensures uninterrupted operation during maintenance periods.
The system’s energy-efficient design and extended consumable lifecycles (with RO modules lasting 24-36 months) significantly reduce running costs compared to conventional systems.
With continuous recirculation technology that prevents bacterial growth during idle periods and real-time monitoring capabilities, the R200 maintains water quality integrity while minimizing labor requirements, providing laboratories with a reliable, economical, and high-performance water purification solution.
The MEDICA® R200 delivers exceptional water purification capacity with output ranging from 18 to 21 liters per minute of CLRW standard water, making it ideal for high-volume clinical laboratory environments.
Its integrated 350-liter reservoir ensures continuous supply while maintaining critical quality parameters (<10 CFU/ml bacterial content, <30 ppb organics). The system can support multiple diagnostic analyzers simultaneously through its distribution loop capability that extends up to 200 meters throughout a facility.
This impressive output capacity combined with consistent quality delivery positions the MEDICA® R200 as the optimal solution for laboratories requiring reliable, high-volume purified water for sensitive diagnostic procedures.
The MEDICA® R200 achieves its impressive 21 liters per minute flow rate through a sophisticated multi-stage purification process that includes high-capacity pre-filtration, industrial-grade reverse osmosis membranes, and advanced UV sterilization technology.
Its integrated 350-liter reservoir serves as both storage and pressure stabilization, allowing consistent high-volume output while maintaining CLRW quality standards. The system employs continuous recirculation technology that constantly moves water through the purification pathway even during periods of low demand, preventing bacterial proliferation and ensuring immediate availability of compliant water.
This advanced engineering is complemented by precision flow control systems that regulate pressure and volume to deliver 18-21 L/min of purified water that consistently meets or exceeds all clinical laboratory reagent water requirements.
The MEDICA® R200 utilizes several replaceable components to maintain water quality:
APPLIED PHYSICS TECHNICAL RESOURCE
Laboratory water quality, purification architecture, distribution, biofilm control and application-led system selection. Product and standards references should be interpreted for the actual instrument, facility, protocol and configuration.
Enter your details below to save your shopping cart for later. And, who knows, maybe we will even send you a sweet discount code :)