Applied Physics · Precision technologies since 1992
Request Quote

Cleanroom Foggers Comparison

Smoke Studies and Airflow Visualization Study Type of Fog Produced Visual Fog Volume Approximate Milli-liters of Liquid converted to Fog / Minute Typical Visible Fog Time (dependent on fog velocity, fog volume and room humidity) Typical Fog Distance What Liquids are Used Typical Shipping Dimensions of main Box Accessories Power Connections
CRF2-H Portable Cleanroom Fogger Low-cost, 9 ultrasonic piezos, single 60mm fog outlet, pure fog output, polyethylene enclosure. Used in fume hood, small glove box, small airflow hood. about 0.28 cubic meters / minute About 50 ml liquid converted to fog each minute (fog density) using 9 ultrasonic piezo devices.
One 60mm fog outlet.
WATCH CRF2 VIDEO
typical, 45 minutes Typical 6-7 feet visual fog airflow De-ionized Water, Sterile Water or WFI (Water for Injection) Water. CRF2-H ships in box, or optionally in a 33x28x17" Rolling Carry Case. 4 optional accessories. 1) 22" Fog Curtain Wand
2) 10 ft Remote Control Cable
3) Rolling Carry Case w/ Foam Insert
4) Drain & Dry Kit.
Separate Power Supply & Cable, 115 VAC, 60 Hz; 220 VAC, 50 Hz.
CRF2-J Portable Cleanroom Fogger with 2Mx80mm Fog Hose Low-cost, 12 ultrasonic piezos, single 80mm fog outlet, pure fog output, polyethylene enclosure. Used in medium glove box, RAB, small BSC, small airflow hood. about 0.43 cubic meters / minute About 64 ml liquid converted to fog each minute (fog density) using 12 ultrasonic piezo devices.
One 80mm fog outlet and Wireless Remote On/Off Key Fob.
WATCH CRF2 VIDEO
typical, 35 minutes Typical 8-10 feet visual fog airflow De-ionized Water, Sterile Water or WFI (Water for Injection) Water. CRF2-J ships in box, or optionally in a 33x28x17" Rolling Carry Case. 12 optional accessories. 1) 80mm x 0.6 M Fog Wand
2) Wireless Remote Control
3) 2M x 80mm Fog Hose
4) Dual 2M x 50mm Hose + 0.6M Fog Wand
5) Y Adaptor w/ Butterfly Valves
6) Plain Y Adaptor
7) 80mm T Adaptor
8) LED Fog Contrast Light
9) Accessory Rolling Carry Case w/ Foam Insert
10) 80mm x 2.4M Fog Wand for BSC, Isolator, cleanroom
11) 250mm Fog Nozzle
12) Drain & Dry Kit.
Integrated Power Supply & Power Cable, 115 VAC, 60 Hz; 100 VAC, 50 Hz; 220 VAC, 50 Hz.
CRF3 Portable Cleanroom Fogger Adjustable control, pure fog output, single 80mm fog outlet, 316L electro-polished brushed stainless steel enclosure with Carry Handles. Used in small BSC, Barrier isolator, RABs, medium glove box smoke studies. about 0.89 cubic meters / minute about 133.57 ml liquid converted to fog each minute (fog density) using 25 ultrasonic piezo devices.
One 80mm fog outlet with 80mm hoses and 50mm hose adaptors.
Adjustable fog volume and airflow velocity, optional wireless remote control.
WATCH CRF4 FOGGER VIDEO
WATCH Ultrasonic Fog Discussion & CRF4 Bio-Safety Cabinet VIDEO
typical, 70 minutes at max fog volume Typical about 10 feet visual fog airflow De-ionized Water, Sterile Water or WFI (Water for Injection) Water. CRF3 ships in box, 32 x 18.5 x 19 inches. Accessories in a separate Rolling Carry Cases. 1) 80mm x 1.2 M Fog Wand
2) Wireless Remote Control
3) 5M x 80mm Fog Hose
4) Dual 5M x 50mm Hose + 0.6M Fog Wand
5) Y Adaptor w/ Butterfly Valves or plain Y Adaptor
6) 80mm T Adaptor
7) LED Fog Contrast Light
8) Accessory Rolling Carry Case w/ Foam Insert
9) 80mm x 2.4M Fog Wand for BSC, Isolator, cleanroom
10) 250mm Fog Nozzle
11) Drain & Dry Kit.
Integrated Power Supply & Power Cable, 115 VAC, 60 Hz; 100 VAC, 50 Hz; 220 VAC, 50 Hz.
CRF6 Portable Cleanroom Fogger Adjustable control, pure fog output and DUAL 80mm fog outlets, 316L electro-polished brushed stainless steel enclosure with Carry Handles. Used in medium USC, RAB, Barrier Isolator, small cleanroom or sterile smoke studies. about 2.0 cubic meters / minute about 213.7 ml liquid converted to fog each minute (fog density) using 40 ultrasonic piezo devices.
Two 80mm fog outputs with 80mm hoses and 50mm hose adaptors.
Adjustable fog volume and airflow velocity, optional wireless remote control.
WATCH CRF4 FOGGER VIDEO
WATCH Ultrasonic Fog Discussion & CRF4 Bio-Safety Cabinet VIDEO
typical, 35 minutes at max fog volume or 50 minutes at lowest fog volume Typical 12-15 feet visual fog airflow De-ionized Water, Sterile Water or WFI (Water for Injection) Water. CRF6 ships in box, 32 x 18.5 x 19 inches. Accessories in a separate Rolling Carry Cases. 1) 80mm x 1.2 M Fog Wand
2) Wireless Remote Control
3) 5M x 80mm Fog Hose
4) Dual 5M x 50mm Hose + 0.6M Fog Wands
5) Y Adaptor w/ Butterfly Valves; or plain Y Adaptor
6) 80mm T Adaptor
7) LED Fog Contrast Light
8) Accessory Rolling Carry Case w/ Foam Insert
9) 80mm x 2.4M Fog Wand for BSC, Isolator, cleanroom
10) 500mm Fog Nozzle
11) Drain & Dry Kit.
Integrated Power Supply & Power Cable, 115 VAC, 60 Hz; 100 VAC, 50 Hz; 220 VAC, 50 Hz.
AP35 Portable Cleanroom Ultrapure Fogger Provides a high volume of ultrapure fog using LN2 + (DI, Sterile or WFI) water, packaged in a 316L electro-polished, brushed, stainless steel enclosure on rolling SS frame (trolley). Used in smoke studies of large clean rooms and for visual fog in stage acting. about 5.5 cubic meters / minute about 571 ml liquid converted to fog each minute (fog density).
Adjustable fog volume, flow control, optional wireless remote control.
2 internal water heaters and ONE 80mm fog outlet.
Includes LN2 FLOW CONTROL to prevent LN2 valve freezing.
WATCH AP35 VIDEO
Typical 70 minutes Typical 20-30 feet visual fog airflow LN2 + De-ionized Water, Sterile Water or WFI (Water for Injection) Water. AP35 ships in crate: 1.2 M x 1M x 0.8 M. Accessories are in separate rolling carry cases. 1) 80mm x 1.2 M Fog Wand
2) Wireless Remote Control
3) 5M x 80mm Fog Hose
4) Dual 5M x 50mm Hose + 0.6M Fog Wands
5) Y Adaptor w/ Butterfly Valves; or plain Y Adaptor
6) 80mm T Adaptor
7) LED Fog Contrast Light
8) Accessory Rolling Carry Case w/ Foam Insert
9) 80mm x 2.4M Fog Wand for BSC, Isolator, cleanroom
10) 500mm Fog Nozzle
11) Drain & Dry Kit.
Integrated Power Supply & Power Cable, 115 VAC, 60 Hz; 100 VAC, 50 Hz; 220 VAC, 50 Hz.
AP100 Portable LN2 Fogger Provides highest volume of ultrapure fog using LN2 + (DI, Sterile or WFI) water, packaged in a 316L electro-polished, brushed, stainless steel enclosure on rolling SS frame (trolley). Used in smoke studies of large clean rooms and for visual fog in stage acting. about 15.5 cubic meters / minute about 1520 ml liquid converted to fog each minute (fog density).
Adjustable fog volume and airflow velocity, optional wireless remote control.
2 internal water heaters and four 80mm fog outputs.
Includes LN2 FLOW CONTROL to prevent LN2 valve freezing.
Typical 90 minutes Typical 30-40 feet visual fog airflow LN2 + De-ionized Water, Sterile Water or WFI (Water for Injection) Water. AP100 ships in crate: 1.2 M x 1.2 M x 1.2M. Accessories are in separate rolling carry cases. 1) 80mm x 1.2 M Fog Wand
2) Wireless Remote Control
3) 5M x 80mm Fog Hose
4) Four 5M x 50mm Hose + 0.6M Fog Wands
5) Y Adaptor w/ Butterfly valves or plain Y Adaptor
6) 80mm T Adaptor
7) LED Fog Contrast Light
8) Accessory Rolling Carry Case w/ Foam Insert
9) 80mm x 2.4M Fog Wand for BSC, Isolator, cleanroom
10) 500mm Fog Nozzle
11) Drain & Dry Kit
12) Spare Dewar w/ SS valve control.
Integrated Power Supply & Power Cable, 115 VAC, 60 Hz; 100 VAC, 50 Hz; 220 VAC, 50 Hz.
Ultrapure LN2 Fogger from 2001 era Medium fog volume. about 1.5 cubic meters / ultrapure fog minute about 250ml liquid converted to fog each minute (fog density).
Does not have LN2 Flow Control to prevent LN2 valve freezing.
Uses only 1 water heater and does not have Wireless Remote control.
1 internal water heater and 1 fog output.
Typical 40 minutes Typical 10-15 feet visual fog airflow LN2 + De-ionized Water, Sterile Water or WFI (Water for Injection) Water. Not Known. 80mm x 0.6M fog wand. 115 VAC, 60 Hz; 220 VAC, 50 Hz; 100VAC, 50 Hz.
CO2 Fogger Low Cost fogger. For barrier isolators, bio-safety cabinets, fume hoods, glove boxes. starts at about 0.30 cubic meters / minute, decreasing to 0 volume as CO2 evaporates over 8 minutes starting at 20 ml / minute, and decreasing to 0 fog density as CO2 ice evaporates to zero. Typical 8-10 minutes Typical 4-6 feet visual fog airflow CO2 ice + De-ionized Water, Sterile Water or WFI (Water for Injection) Water. CO2 fogger ships in 22 x 22 x 18" Case. Carry Case
Fog Wand
Ice Maker.
115 VAC, 60 Hz; 220 VAC, 50 Hz.
Low Cost, Hand Held, Glycol Fogger Glycerin liquid and Water. Typically used in industrial and FDA applications. May leave a glycol film on surfaces, unless wiped clean. about 0.30 cubic meters / minute about 1.0 to 1.5 ml fog density / minute. Typical 45 minutes Typical 10-15 feet visual fog airflow 10% Glycerin liquid and 90% water, (Sterile, deionized or WFI). Portable Fogger ships in box, 20 x 18 x 12 inches. All Accessories included in carry case. Includes all accessories including:
Fog Wand
Carry Case
Power Charger
rechargeable Lithium ion battery
fog hose extension
bottle and filling tools.
Rechargeable Battery, 115V/220V Charging in 60 Minutes.

Feature / Fogger Comparison

Feature / Fogger AP30 Ultrapure Fogger AP50 Ultrapure High-Performance LN₂ Fogging for Airflow Visualization & Validation AP200 Ultrapure - Maximum Fog Volume for Large-Scale Cleanroom Validation Other LN₂ Foggers Alternative Foggers
Fog Volume 4.3 m³/min 7.1 m³/min 28.6 m³/min 15-20 m³/min 3.5-10 m³/min
Fog Purity 100% Ultrapure LN₂ fog 100% Ultrapure LN₂ fog 100% Ultrapure LN₂ fog Ultrapure LN₂ Fog Chemical-Based Fog
Run Time 60 min 75 min 105 min 60-75 min 30-50 min
Residue-Free Yes Yes Yes Yes No
Portable Design Yes Yes Yes Often Bulkier Varies
ISO/GMP Compliance Yes Yes Yes Yes Some

Model Specifications

Model Tank/Water Size # Piezos Output Size Fog Output Volume (m³/min) Water Consumption (ml/min) Output Distance (Est.) Notes
CRF2-H 5–10 L 9 Single 60mm 0.26 48.1
CRF2-J 5–10 L 12 Single 80mm 0.56 64.1
CRF4 20 L 35 Single 80mm 1.25 187
Old CRF3 9–11 L 25 Single 80mm 0.9 133.5
New CRF3 9–11 L 24 Dual 80mm 1.2

Cleanroom Foggers Fog Comparison

Model Design / Enclosure Fog Application Fog Volume (m3/min) Duration (min) Duration Display Fog View Distance Fog Outlets Status Notes Accessories Power / Notes
CRF2-H Polyethylene enclosure, 9 ultrasonic piezos, single 60mm outlet Fume hoods, small glove boxes, small airflow hoods 0.28 45 45 6-7 feet One 60mm fog outlet Current 22" fog curtain wand; 10 ft remote cable; rolling carry case; drain & dry kit DI / Sterile / WFI water; separate power supply; 115/220 VAC
CRF2-J Polyethylene enclosure, 12 ultrasonic piezos, single 80mm outlet Medium glove boxes, RABs, small BSCs, small airflow hoods 0.43 35 35 8-10 feet One 80mm fog outlet Current 0.6M 80mm wand; wireless remote; 2M x 80mm hose; Y/T adaptors; LED light DI / Sterile / WFI water; integrated power; 115/100/220 VAC
2022 CRF3 (Discontinued) 316L electro-polished stainless enclosure, 25 ultrasonic piezos, single 80mm outlet Small BSCs, barrier isolators, RABs, medium glove boxes 0.89 70 70 about 10 feet One 80mm fog outlet Discontinued 80mm wand; wireless remote; 5M x 80mm hose; dual 50mm hose set; Y/T adaptors; LED light DI / Sterile / WFI water; integrated power; 115/100/220 VAC
2025 CRF3 (Current) 316L electro-polished stainless enclosure, 24 ultrasonic piezos, dual 80mm outlets Small / medium BSCs, barrier isolators, RABs, medium glove boxes 1 62 62 10-12 feet Two 80mm fog outlets Current Runtime estimated from 2022 CRF3 using inverse fog-volume scaling. 80mm wand; wireless remote; 5M x 80mm hose; dual 50mm hose set; Y/T adaptors; LED light DI / Sterile / WFI water; integrated power; 115/100/220 VAC
Legacy CRF4 316L electro-polished stainless enclosure, 35 ultrasonic piezos, single 80mm outlet Medium BSCs, barrier isolators, RABs, medium cleanroom smoke studies 1.4 45 45 12-15 feet One 80mm fog outlet Discontinued Runtime estimated from 2022 CRF3 using inverse fog-volume scaling. 80mm wand; wireless remote; 5M x 80mm hose; dual 50mm hose set; Y/T adaptors; LED light; drain & dry kit LN2 + DI / Sterile / WFI water; integrated power; 115/100/220 VAC
2022 CRF6 (Discontinued) 316L electro-polished stainless enclosure, 40 ultrasonic piezos, dual 80mm outlets Medium BSCs, RABs, barrier isolators, small cleanrooms, sterile smoke studies 2 35 35 12-15 feet Two 80mm fog outlets Discontinued 80mm wand; wireless remote; 5M x 80mm hose; dual 50mm hose set; Y/T adaptors; LED light; drain & dry kit LN2 + DI / Sterile / WFI water; integrated power; 115/100/220 VAC
2025 CRF6 (Current) 316L electro-polished stainless enclosure, 48 ultrasonic piezos, dual 80mm outlets Medium / large BSCs, RABs, barrier isolators, small cleanrooms, sterile smoke studies 2.4 26 26 14-17 feet Two 80mm fog outlets Current Runtime estimated from 2022 CRF3 using inverse fog-volume scaling. 80mm wand; wireless remote; 5M x 80mm hose; dual 50mm hose set; Y/T adaptors; LED light; drain & dry kit LN2 + DI / Sterile / WFI water; integrated power; 115/100/220 VAC
AP35 316L electro-polished stainless trolley unit, self-pressurized 35L tank, dual heaters, dual 80mm outlets Small ISO suites, medium barrier isolators, glove boxes 8.5 70 70 15-20 feet Two 80mm fog outlets Current 80mm wand; wireless remote; 5M x 80mm hose; dual 50mm hose set; Y/T adaptors; LED light; drain & dry kit LN2 + DI / Sterile / WFI water; integrated power; 115/100/220 VAC
AP30 316L electro-polished stainless trolley unit, self-pressurized 30L tank, dual heaters, dual 80mm outlets Small ISO suites, medium barrier isolators, glove boxes 7.4 60 60 15-20 feet Two 80mm fog outlets Current 80mm wand; wireless remote; 5M x 80mm hose; dual 50mm hose set; Y/T adaptors; LED light; drain & dry kit LN2 + DI / Sterile / WFI water; integrated power; 115/100/220 VAC
AP50 316L electro-polished stainless trolley unit, self-pressurized 50L tank, dual heaters, dual 80mm outlets Small / medium ISO suites, medium barrier isolators, glove boxes 12.2 75 75 18-22 feet Two 80mm fog outlets Current 80mm wand; wireless remote; 5M x 80mm hose; dual 50mm hose set; Y/T adaptors; LED light; drain & dry kit LN2 + DI / Sterile / WFI water; integrated power; 115/100/220 VAC
AP95 316L electro-polished stainless trolley unit, passive 95L tank platform, dual heaters, dual 80mm outlets Medium / large ISO suites, barrier isolators, large glove boxes, cleanroom airflow validation 15.2 89 89 18-21 feet Two 80mm fog outlets Current Passive 95L estimate aligned to corrected AP-family baseline logic. 80mm wand; wireless remote; 5M x 80mm hose; dual 50mm hose set; Y/T adaptors; LED light; drain & dry kit LN2 + DI / Sterile / WFI water; integrated power; 115/100/220 VAC
Legacy AP100 316L electro-polished stainless trolley unit, passive 100L tank platform, dual heaters, dual 80mm outlets Medium / large ISO suites, barrier isolators, large glove boxes and BSCs 16 90 90 18-21 feet Two 80mm fog outlets Discontinued Passive 100L baseline aligned to corrected AP-family logic. 80mm wand; wireless remote; 5M x 80mm hose; dual 50mm hose set; Y/T adaptors; LED light; drain & dry kit LN2 + DI / Sterile / WFI water; integrated power; 115/100/220 VAC
AP100 316L electro-polished stainless trolley unit, self-pressurized 100L tank, dual heaters, dual 80mm outlets Medium / large ISO suites, barrier isolators, large glove boxes and BSCs 20.5 90 90 22-26 feet Two 80mm fog outlets Current 80mm wand; wireless remote; 5M x 80mm hose; dual 50mm hose set; Y/T adaptors; LED light; drain & dry kit LN2 + DI / Sterile / WFI water; integrated power; 115/100/220 VAC
AP175 316L electro-polished stainless trolley unit, passive 175L tank platform, dual heaters, dual 80mm outlets Large ISO suites, large cleanrooms, large barrier isolators, large-scale airflow validation 28 101 101 24-27 feet Two 80mm fog outlets Current Passive 175L extrapolated from corrected AP-family baseline logic. 80mm wand; wireless remote; 5M x 80mm hose; dual 50mm hose set; Y/T adaptors; LED light; drain & dry kit LN2 + DI / Sterile / WFI water; integrated power; 115/100/220 VAC
AP200 316L electro-polished stainless trolley unit, self-pressurized 200L tank, dual heaters, dual 80mm outlets Large ISO suites, large cleanrooms, large barrier isolators, large-scale airflow validation 49 105 105 33-37 feet Two 80mm fog outlets Current Distance shown marketing-forward from corrected 200L projection. 80mm wand; wireless remote; 5M x 80mm hose; dual 50mm hose set; Y/T adaptors; LED light; drain & dry kit LN2 + DI / Sterile / WFI water; integrated power; 115/100/220 VAC
Current Applied Physics Fogger Family

CRF ultrasonic or AP Series LN₂?

Use this matrix as a starting point. Product selection should follow the current quoted configuration and the actual study geometry; restrictive delivery paths should never be sized from a room-volume or free-air figure alone.

ModelTechnologyBest starting pointSelection status / fact
CRF2UltrasonicLocalized studies, hoods, small enclosuresCompact current CRF platform; confirm the quoted product sheet.
CRF3UltrasonicMid-range cleanroom / enclosure studiesMid-range current CRF platform; confirm the quoted product sheet.
CRF6UltrasonicHigher-output portable ultrasonic studies48 piezos · dual 80 mm outlets · ≈2.4 m³/min · 7-inch HD display.
AP35LN₂ · passive/dewar35 L passive/dewar AP Series optionCurrent passive/dewar architecture.
AP30LN₂ · self-pressurizedCompact self-pressurized AP Series optionCurrent self-pressurized architecture; not a replacement for AP35.
AP50LN₂ · self-pressurizedIntermediate self-pressurized AP Series optionCurrent self-pressurized platform; confirm quoted performance.
AP95LN₂ · passive/dewarHigher-capacity passive/dewar AP optionCurrent passive/dewar platform; confirm quoted performance.
AP175LN₂ · passive/dewarLargest passive/dewar AP Series optionCurrent passive/dewar platform; confirm quoted performance.
AP100LN₂ · self-pressurizedHigher-capacity self-pressurized AP optionCurrent self-pressurized platform.
AP200LN₂ · self-pressurizedLargest self-pressurized AP Series optionCurrent self-pressurized platform for larger-scale planning.
AP Series architecture note:

AP Series LN₂ foggers are offered in two current architecture families. Self-pressurized models include AP30, AP50, AP100 and AP200. Passive/dewar-style models include AP35, AP95 and AP175. Choose the architecture from the application, handling preference, study duration and fog-delivery path rather than treating one architecture as the successor to the other.

Self-pressurized AP Series →   Passive/dewar AP Series →

Delivered fog matters more than free-air output.

Hose length, diameter, bends, Y/T adapters, a restrictive injection port and enclosure pressure can all reduce or redistribute the fog that actually reaches the test area. For isolators and RABS, evaluate the intended delivery path under representative pressure conditions.

The quote should identify the actual application, enclosure/room dimensions, pressure relationship, hose/port geometry and study objective so Applied Physics can recommend the appropriate configuration.

Technology Selection

Use CRF for ultrasonic portability; use AP Series when LN₂-based fog is the requirement

CRF Series · Ultrasonic

CRF2, CRF3 and CRF6 generate visible fog ultrasonically from the appropriate water supply. The family spans compact localized studies through the confirmed high-output CRF6.

  • No LN₂ required.
  • Portable cleanroom airflow visualization.
  • CRF6 confirmed: 48 piezos, dual 80 mm outlets, ≈2.4 m³/min, 7-inch HD display.

AP Series · LN₂

The current AP Series is organized by architecture: self-pressurized AP30, AP50, AP100 and AP200, and passive/dewar AP35, AP95 and AP175. Select between architectures based on the actual study and handling requirement.

  • LN₂-based tracer generation.
  • Select capacity around the real study, not a marketing maximum.
  • Confirm current quoted product-sheet performance before procurement.
Delivered fog matters more than free-air output.

Hose length, diameter, bends, Y/T adapters, a restrictive injection port and enclosure pressure can all reduce or redistribute the fog that actually reaches the test area. For isolators and RABS, evaluate the intended delivery path under representative pressure conditions.

CRF2CRF3CRF6AP30AP50AP95AP100AP200
Fogger Sizing · Application First

Do not size a cleanroom fogger from room volume alone

Room or enclosure volume is useful context, but it does not describe the resistance between the fogger and the point where the tracer must be visible. The sizing decision should capture the complete delivery path and the evidence the study needs to produce.

1 · Geometry

  • Room, RABS, isolator, BSC or hood
  • Approximate dimensions / volume
  • Fog injection point and critical zone
  • Required visible travel distance

2 · Restriction

  • Port diameter
  • Hose diameter and length
  • Number of bends / adapters
  • Pressure differential or exhaust pull

3 · Study objective

  • Static vs dynamic operation
  • Interventions to visualize
  • Required runtime / number of shots
  • Camera and lighting plan
Delivered fog matters more than free-air output.

Hose length, diameter, bends, Y/T adapters, a restrictive injection port and enclosure pressure can all reduce or redistribute the fog that actually reaches the test area. For isolators and RABS, evaluate the intended delivery path under representative pressure conditions.

Two outlets into one hose?

Combining two fogger outlets through a reverse Y into a single downstream hose can add restriction and backpressure. Where practical, preserve separate delivery paths or use a manifold/downstream line sized for the combined flow. If a combined line is required, validate that exact hose and enclosure configuration before the formal study.

Plan the StudyDownload Study Checklist
Fog Delivery Accessories

Treat hoses, wands and adapters as part of the airflow-visualization system

The same fogger can behave very differently depending on how the fog is delivered. The accessory plan should support visibility without creating a tracer jet that overpowers the airflow being observed.

Hoses

Use the shortest practical route and avoid unnecessary reductions. Long flexible runs and small downstream diameters increase resistance.

Wands / nozzles

Use a wand, curtain or diffuser when the study needs fog distributed across a wider region or introduced at lower local momentum.

Y / T adapters

Use splitters to serve multiple injection points only after considering the resulting balance and restriction. Valved branches can help tune the distribution.

For isolators and RABS

  • Match adapters to the actual penetration.
  • Keep the delivery hose supported and repeatable.
  • Record the hose/adapter configuration in the study setup.
  • Test through the real pressure boundary before formal video.

For video quality

  • Improve backlighting before adding excessive tracer.
  • Use a wide-output wand where local jetting hides the true pattern.
  • Keep hoses and technicians out of the camera field when practical.
  • Preserve the same accessory setup for repeat shots.
You were not leaving your cart just like that, right?

You were not leaving your cart just like that, right?

Enter your details below to save your shopping cart for later. And, who knows, maybe we will even send you a sweet discount code :)

Want to receive personalized offers?

Allow notifications to get real-time updates about your shopping cart and who knows, you may even receive a sweet discount code 😊

Maybe later