Biological safety cabinet is a box-type air purification negative pressure safety device that can prevent the aerosol escape of some dangerous or unknown biological particles in the process of experimental operation. It is widely used in scientific research, teaching, clinical testing and production in the fields of microbiology, genetic engineering and biological products, and is the most basic safety protection equipment in the first-level protective barrier of laboratory biosafety.

Features: 1. Color key display: large screen, more clear and dynamic display of various values of the safety cabinet, and has the function of appointment timing. 2. Automatically adjust the wind speed. 3. With power-off memory function, the state before power-off will be restored after power-on, and there will be visual prompts and alarms. 4. The integrated design of the operation area makes it easy to disassemble and clean. 5. The cabinet is separated from the base. The height of the adjustable base can be customized. 6. Interlocking function: UV lamp and front window, UV lamp and fan, LED lamp, fan and front window. 7. It has the function of appointment timing, which can automatically set the time of starting and shutting down the safety cabinet and the running time of ultraviolet lamps, fans and sockets. 8. The front window closes the double trigger signal, so that the sterilization and disinfection function of the ultraviolet lamp is normally turned on. 9. The negative pressure air duct is equipped with a foreign matter filtering structure to prevent foreign matter such as paper scraps from entering the fan system and affecting the normal operation of the product. 10. The front window glass has a one-key lift function. 11. The one-piece hand resting surface has a larger contact area with the arm and is more comfortable.

AC Series Class II A2 Biological Safety Cabinet

Technical Parameters:

ModelBSC-700IIA2-Z
External Size(W*D*H)700*650*1920mm(700*650*1280mm without base stand)
Internal Size(W*D*H)600*500*540mm
Tested OpeningSafety height 200mm
Max Opening380mm
Inflow Velocity0.53±0.025m/s
Down Flow Velocity0.33±0.025m/s
ULPA FilterTwo, 99.9995% efficiency at 0.12μm, filter life indicator
Front WindowMotorized
Noise≤65dB
UV Lamp15W*1 UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination
LED Lamp8W*2
Illumination≥1000Lux
Consumption≤500W
SocketTwo, total load of two sockets: 500W
DisplayLCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time, etc
Control System70% air recirculation, 30% air exhaust
Visual and Audio AlarmFilter replacement, window over height, abnormal air flow velocity, high filter pressure alarm, abnormal power failure
MaterialWork Zone: 304 stainless steel Main Body: Cold-rolled steel with anti-bacteria power coating
Work Surface Height750mm with base stand
Power SupplyAC220V, 50/60Hz; 110V, 60Hz
Standard AccessoryCabinet*1, LED lamp*2, UV lamp*2, Remote control, Drain valve*1, Waterproof socket*2, Foot swith
Optional AccessoryWater and gas tap, Electric height adjustable base stand, Armrest, Base stand*1
Package Size(W*D*H)Without Base Stand800*760*1470mm
With Base stand800*900*1470mm
Gross WeightWithout Base Stand125kg
With Base stand141kg

Product relationship

Available Through Applied Physics

Applied Physics supplies and supports quotation of this product. Product branding and manufacturer information, where stated on the product page or supporting documentation, remain authoritative.

Applied Physics portfolio: Medical

Biological safety cabinet quote checklist

Confirm cabinet class/type, biological agents or procedures, chemical use, work opening, exhaust/ducting requirement, room HVAC interaction, electrical service and certification/documentation requirements.

Catalog relationship: Available Through Applied Physics

Related Applied Physics resources

Continue through the Medical portfolio

Use these technical and portfolio pages to compare applications and related equipment. To keep this exact product attached to an RFQ, use the product’s existing Request a Quote or Add To Order control.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

You were not leaving your cart just like that, right?

You were not leaving your cart just like that, right?

Enter your details below to save your shopping cart for later. And, who knows, maybe we will even send you a sweet discount code :)

Want to receive personalized offers?

Allow notifications to get real-time updates about your shopping cart and who knows, you may even receive a sweet discount code 😊

Maybe later