Description
Benchtop pH/ORP/lon Meter PH-920 PH-930
pH:
1. 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
2. Automatic electrode diagnosis shows the pH slope and offset.
3. Automatic temperature compensation ensures accurate readings over the entire range.
4. Calibration due alarm prompts user to calibrate the meter regularly.
ORP:
1. 1 point offset calibration allows adjusting the displayed value to a known standard.
2. Relative and absolute millivolt modes ensure the reliable ORP measurements. Ion Concentration(For PH-930).
3. 2 to 5 points calibration, including the 8 concentration points can be selected.
4. Direct ion concentration readout simplifies the measurement process.
5. Automatic electrode diagnosis shows the calibration points and slopes.
6. Selectable concentration units(ppm, mg/L, mol/L, mmol/L) and ionic valency.
General Features:
1. Auto-Read function senses and locks the measurement endpoint.
2. Setup menu allows setting the pH buffer set, number of calibration points, resolution, stability criteria, temperature unit, date and time, etc.
3. Reset function automatically resumes all settings back to the factory defaults.
4. Expanded memory stores or recalls up to 500 data sets.
5. USB communication interface for data transfer and timed interval readings.
Accessories:
E201-BNC plastic body pH electrode, temperature probe, pH buffer sachets, electrode holder, DC5Vpower adapter.
Technical Parameters:
Model
PH-920
PH-930
PH
Range
-2.000~20.000pH
Accuracy
±0.002pH
Resolution
0.1, 0.01, 0.001pH, Selectable
Calibration Points
1~5 points
Calibration Solutions
USA, NIST, DIN, 2 custom buffers
ORP
MV Range
±1999.9mV
Relative mV Range
±1999.9mV
Resolution
0.1,1mV, Selectable
MV Accuracy
±0.2mV
Calibration Points
1 point
Ion
Range
/
0.001~19999ppm, mg/L, mol/L(deponding on the range of ISE)
Resolution
/
0.001, 0.01 ,0.1, 1
Accuracy
/
±0.5%F.S(Monovalent),
±1%F.S(Divalent)
Measurement Units
/
ppm, mg/L, mol/L, mmol/L
Calibration Points
/
2 to 5 points
Calibration Solutions
/
0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000
Temperature
Range
0~105°C/32~221°F
Resolution
0.1°C/0.1°F
Accuracy
±0.5°C/±0.9°F
Offset Calibration
1 point, reading ±10°C
Other
Specifications
Temperature Compensation
0~100°C, Manual or Automatic
Stability Criteria
Low or high
Calibration Due Alarm
1 to 31 days or off
Slope/Offset Display
Yes
Hold Function
Manual or auto-endpoint
Memory
500 data sets
Communication Interface
USB
Connector
BNC, 3.5mm jack socket
Display
Custom LCD(125*100mm)
Power Requirements
DC5V power adapter
Dimensions(mm)
210*188*60mm
Weight(kg)
1.5kg
Package Size(W*D*H)mm
310*240*180mm
Gross Weight(kg)
1.7kg











Reviews
There are no reviews yet.