Description
It is suitable for general operating room, delivery room, blood ward, burn ward, protective isolation ward, intensive care unit, disinfection supply center, intensive dialysis center, examination room, treatment room, infectious disease consultation.
Features: 1. The coexistence of man and machine means that it can be disinfected in a manned environment or in an unmanned environment. 2. LCD touch display, real-time display of indoor temperature and humidity(Humidity only for BKB-G-1600-D). 3. 6 groups of on-off time can be booked within 24 hours, wind speed can be adjusted in three APM. 4. Manual, timing, temporary and automatic working modes(Automatic working mode only for BKB-G-1600-D) are available. 5. With two-section plasma generator, the upper part uses 4000V plasma generator to adsorb dust particles, and the lower part uses 8000V plasma generator to sterilize and disinfect(Mobile type). With plasma generator, fan, negative ion module fault alarm, filter maintenance warning(BKB-G-1600-D). The service life can reach 30000 hours. 6. Built-in high-concentration negative-ion generator, release negative ions to adsorb dust particles in the air and purify the air. 7. The device has two fans and two plasma generators with large air volume and space disinfection capacity(Only for BKB-G-1600-D). 8. Filter is easy to disassemble. Technical Parameters:
| Model | BKB-Y-800-D | BK-Y-1000-D | BKB-G-1600-D |
| Type | Mobile type | Floor type | |
| Disinfection Type | Plasma and electrostatic adsorption | ||
| Applicable Space | ≤80m3 | ≤100m3 | ≤160m3 |
| Circulating Air | ≥800m3/h | ≥1000m3/h | ≥1600m3/h |
| Shell Material | ABS shell | Metal shell | |
| Ozone Leakage | ≤0.01mg/m³ | ≤0.033mg/m3 | ≤0.01mg/m³ |
| Plasma Density | 3.40*10^17m-3~1.75*10^18m-3 | 3.49*10^17m-3~8.67*10^17m-3 | 3.38*10^17m-3~1.84*10^18m-3 |
| Negative Ion Generation | ≥5*10^6pcs/cm3 | ||
| Electric Field Intensity of Sterilization Area | 8000V | ||
| Electric Field Intensity of Dust Accumulation Area | 4000V | ||
| Natural Bacteria Extinction Rate | ≥90% | ||
| Sterilization Rate of Staphylococcus Albus | ≥99.9% | ||
| Noise | ≤55dB(A) | ||
| Consumption | ≤100W | ≤200W | |
| Power Supply | AC220V, 50/60Hz(Standard); AC110V, 50/60Hz(Optional)(External transformer) | ||
| External Size(W*D*H) | 370*360*710mm | 540*410*900mm | 370*360*1340mm |
| Net Weight | 20.5kg | 23kg | 41.8kg |
| Package Size(W*D*H) | 440*430*780mm | 574*481*975mm | 440*430*1420mm |
| Gross Weight | 25.3kg | 28.5kg | 47.7kg |
Product relationship
Applied Physics OEM Medical
This is Applied Physics-branded OEM medical or laboratory equipment, contract manufactured for Applied Physics. Applied Physics provides product selection, quotation and customer support.
Applied Physics portfolio: Medical
Disinfection-system quote checklist
Confirm load or room application, material compatibility, capacity, process objective, exposure/cycle requirement, ventilation constraints, utilities and site-specific documentation requirements.
Catalog relationship: Applied Physics OEM Medical
Related Applied Physics resources
Continue through the Medical portfolio
Use these technical and portfolio pages to compare applications and related equipment. To keep this exact product attached to an RFQ, use the product’s existing Request a Quote or Add To Order control.





Reviews
There are no reviews yet.