Description
Features:
1. High-quality material: the sterilization chamber is made of high-quality S30408 stainless steel electropolished.
2. Steam generation method: the main body is heated, no external steam source is required.
3. Operation interface: 3.5-inch capacitive color display screen is used to display pressure, temperature, time, alarm code and other information in real time, which is convenient for users to observe. When the sterilization cycle is over, a buzzer will sound.
4. Sterilization record: standard USB interface, optional printer, record program data.
5. New storage rack: increase the utilization space of the sterilization chamber, and the selection space for sterilization load is larger.
6. Control system: controlled by single chip microcomputer, automatic control of heating, sterilization and exhaust, without too much manual operation.
7. One-key start on the operation panel, using mechanical keys, the number of actions≥100,000 times.
8. Two sterilization procedures at 121°C and 134°C are selectable.

Safety Protection:
Over-temperature automatic protection, heating tube anti-dry protection, safety interlock device, double over-voltage protection, over-current leakage safety protection, door detection protection.
Technical Parameters:
| Model | BKM-K18N | BKM-K23N | |
| Capacity | 18L | 23L | |
| Door | Manual | ||
| Display | 3.5-inch LCD | ||
| Max Designed Pressure | 0.28Mpa | ||
| Working Pressure | 0.23Mpa | ||
| Max Designed Temp. | 150℃ | ||
| Working Temp. | 121/134℃ | ||
| Temp. Precision | 0.1℃ | ||
| Chamber Material | S30408 | ||
| Chamber Size | φ250*350mm | φ250*450mm | |
| Altitude | ≤2500m | ||
| Rack | 1 rack with 3 trays | ||
| Standard Accessories | Aluminum tray, USB port | ||
| Optional Accessories | Stainless steel tray, printer | ||
| Consumption | 1.6KW | ||
| Power Supply | AC220V, 50/60Hz(Standard)
AC110V, 50/60Hz(Optional) |
||
| External Size(W*D*H) | 650*495*410mm | 700*495*410mm | |
| Net Weight | 32kg | 36kg | |
| Package Size(W*D*H) | 810*610*590mm | ||
| Gross Weight | 47kg | 50kg | |
Class N table-top autoclave selection should follow the load and protocol
Autoclave selection is application-specific. Chamber size is only one variable; the load type, cycle, drying requirement, electrical service, documentation needs and facility procedure should be confirmed before purchase.
Load
Define the materials, packaging, instruments or laboratory items that will be processed.
Cycle
Confirm the sterilization, vacuum/drying and documentation requirements required by the facility workflow.
Site
Confirm voltage, installation location, water/utility requirements and available service access.
Questions engineers and validation teams ask
What should be confirmed before selecting a table-top autoclave?
Confirm the load type, required sterilization cycle, chamber capacity, electrical service, drying requirements, documentation needs and facility-specific procedures before selecting a model.
Is a Class N autoclave interchangeable with a Class B autoclave?
No. The appropriate autoclave class depends on the load and required cycle. Selection should be based on the actual items and facility protocol rather than class name alone.






Reviews