Applied Physics · Precision technologies since 1992
Search

Portable Multi parameter Water Quality Meter

Request a Quote

The Portable Multi-Parameter Water Quality Meter is a high-precision instrument designed for on-site water analysis in various environments, including laboratories, environmental monitoring, wastewater treatment plants, and industrial applications.

SKU AP-Portable-Multi-parameter-Water-Quality-M Categories ,

Description

Portable Multi parameter Water Quality Meter Features: PH: 1. Multiparameter water quality meter is equipped with a 3.5 inches backlit LCD display. 2. 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers. 3. Automatic electrode diagnosis shows the pH slope and offset. ORP: 1. 1 point offset calibration allows adjusting the displayed value to a known standard. 2. Relative and absolute millivolt modes ensure the reliable ORP measurements. Ion Concentration: 1. 2 to 5 points calibration, including the 8 concentration points can be selected. 2. Direct ion concentration readout simplifies the measurement process. 3. Automatic electrode diagnosis shows the calibration points and slopes. 4. Selectable concentration units(ppm, mg/L, mol/L, mmol/L) and ionic valency.   Conductivity/TDS/Salinity/Resistivity: 1. 1 to 5 points calibration with automatic recognition for conductivity standards. 2. Selectable cell constant, reference temperature, TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes. 3. Automatic electrode diagnosis shows the calibration points and factors. Dissolved Oxygen: 1. 1 or 2 points calibration using the air-saturated water or zero oxygen solution. 2. Salinity and barometric pressure compensations eliminate the measurement error.  Other Features: 1. Automatic temperature compensation ensures accurate readings over the entire range. 2. Auto-Read function senses and locks the measurement endpoint. 3. Calibration due alarm prompts user to calibrate the meter regularly. 4. Auto-Power Off effectively conserves battery life. 5. Setup menu allows setting the number of calibration points, resolution, stability criteria, temperature unit, date and time, etc.. 6. Reset function automatically resumes all settings back to the factory defaults. 7. Expanded memory stores or recalls up to 500 data sets. 8. USB communication interface is easy to transfer data to PC. 9. Multi-mode power scheme(batteries, power adapter and USB port) ensures that using the meter smoothly.   Accessories: pH/conductivity/dissolved oxygen electrode, temperature probe, pH standard buffer, conductivity standard solutions, dissolved oxygen electrolyte, membrane cap, carrying case.   Technical Parameters: Model PH-900P pH Range -2.000~20.000pH Resolution 0.001, 0.01, 0.1pH, selectable Accuracy ±0.002pH Calibration Points 1 to 5 points pH Buffer Options USA, NIST, DIN, 2 custom buffers ORP(Optional) Range ±1999.9mV Resolution 0.1, 1mV, selectable Accuracy ±0.2mV Calibration Points 1 point lon(Optional) Range 0.001~19999(depending on the range of ISE) Resolution 0.001, 0.01, 0.1, 1 Accuracy ±0.5%F.S.(monovalent),  ±1%F.S.(divalent) Measurement Units ppm, mg/L, mol/L, mmol/L Calibration Points 2 to 5 points(0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) Conductivity Range 0.1~2μS/cm(CON-0.1, optional) 2~20mS/cm(CON-1.standard) 20~200mS/cm(CON-10, optional) Resolution 0.001, 0.01, 0.1, 1 Accuracy ±0.5%F.S. Calibration Points 1 to 5 points Calibration Solutions 10μS/cm, 84μS/cm, 1413μS/cm, 12.88mS/cm, 111.8mS/cm T emperature Coefficient Linear(0.0~10.0%/°C), pure water Reference Temperature 20/25°C Cell Constant K=0.1, 1, 10 or custom TDS Range 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt Resolution 0.01, 0.1, 1 Accuracy ±1%F.S. TDS Factor 0.1~1.0(default 0.5) Salinity Range 0.00~42.00psu, 0.00~80.00ppt Resolution 0.01 Accuracy ±1%F.S. Resistivity Range 0.00~20.00MΩ Resolution 0.01 Accuracy ±1%F.S. DO Range 0.00~20.00mg/L, 0.0~200.0% saturation Resolution 0.01mg/L, 0.1% Accuracy ±0.2mg/L, ±2.0% Calibration Points 1 or 2 points Barometric Pressure Correction 60.0~112.5kPa/450~850mmHg, manual Salinity Correction 0.0~50.0g/L, manual Other Specifications Temperature Compensation 0~100°C/32~212°F, manual or automatic Memory 500 data sets. USB communication interface Power Requirements 3*1.5V AA batteries or DC5V power adapter Dimension 170*85*30mm Net Weight 300g Packing Size 450*320*100mm Gross Weight 2kg

Product relationship

Available Through Applied Physics

Applied Physics supplies and supports quotation of this product. Product branding and manufacturer information, where stated on the product page or supporting documentation, remain authoritative.

Applied Physics portfolio: Medical

Catalog relationship: Available Through Applied Physics

Related Applied Physics resources

Continue through the Medical portfolio

Use these technical and portfolio pages to compare applications and related equipment. To keep this exact product attached to an RFQ, use the product’s existing Request a Quote or Add To Order control.

Additional information

Model

PH-900P

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

You were not leaving your cart just like that, right?

You were not leaving your cart just like that, right?

Enter your details below to save your shopping cart for later. And, who knows, maybe we will even send you a sweet discount code :)

Want to receive personalized offers?

Allow notifications to get real-time updates about your shopping cart and who knows, you may even receive a sweet discount code 😊

Maybe later