How Stand KOACH C-645-F and C-900-F Deliver Portable ISO Class 1 Cleanliness

Laboratories and manufacturing facilities often require extremely clean conditions for sensitive processes.

Building a complete cleanroom is expensive, time-consuming, and inflexible.

The Stand KOACH C-645-F and C-900-F address this issue by creating a localized ISO Class 1 clean environment anywhere in a room, without walls, ceilings, or permanent installation.

Manufactured by Koken Ltd. in Japan and distributed by Applied Physics USA, these portable systems provide semiconductor fabrication plants, pharmaceutical laboratories, and research facilities with a practical way to achieve the highest level of air cleanliness exactly where it is needed.

What Is the Stand KOACH?

The Stand KOACH is an open, clean-air system consisting of two vertical units positioned facing each other. When placed on opposite sides of a worktable, they create a controlled, clean-air zone between them.

Unlike conventional clean benches that enclose the workspace, the Stand KOACH keeps the working area completely open. Operators can work freely from all sides, move large equipment in and out, and collaborate face-to-face.

Stand KOACH researchers discuss samples in a modern laboratory with microscopes, stainless steel tables

Both the C-645-F and C-900-F models use advanced nanofiber filters called FERENA. These filters remove airborne particles as small as 0.1 micrometers, including many virus-sized particles, and provide ISO Class 1 cleanliness in less than two minutes.

How the Stand KOACH Creates ISO Class 1 Conditions

The technology is simple and effective

  • Each unit draws room air through a pre-filter and the main FERENA nanofiber filter.
  • Clean air is pushed out in a low-velocity, unidirectional flow from the large vertical face of each unit.
  • The two air streams meet in the center and are forced outward horizontally.
  • This colliding airflow keeps the central zone free of particles while continuously sweeping contaminants away from the work surface.
Stand KOACH clean-air system diagram showing low-velocity airflow, particle sweep, and contaminant-free laboratory work surface

Because the clean zone is created by air alone, there are no walls to block access or generate additional particle sources. Contaminants generated by hand movement or tools are carried out of the zone rather than trapped inside.

Key Advantages of the Stand KOACH System

1) True ISO Class 1 Performance

ISO Class 1 is the highest cleanliness rating defined by ISO 14644-1. It allows only a few particles larger than 0.1 μm per cubic meter.

Stand KOACH cleanroom workstation with sterile lab equipment and technicians in a high-tech pharmaceutical production facility

The Stand KOACH reaches this level in less than two minutes and maintains it during normal work activities.

2) Complete Open Access

Operators can work from any angle. Large microscopes, wafer handlers, or process tools can be placed inside the clean zone without restriction.

Stand KOACH lab airflow workstation with scientists using a microscope in a clean research laboratory setting

Face-to-face collaboration is possible, which is difficult with conventional clean benches.

3) Portable and Flexible

Both models roll on casters. A clean zone can be set up in minutes wherever it is needed, in a corner of a lab, next to a production line, or temporarily for a specific project.

Stand KOACH in a clean lab, a technician moves a portable machine beside advanced sterile production equipment

When the work is finished, the units can be moved or stored.

4) Cost and Space Efficiency

Building a permanent ISO Class 1 cleanroom requires significant capital, construction time, and ongoing energy costs.

Stand KOACH clean ISO Class 1 lab with advanced workbenches, testing equipment, and controlled environment for precision research

The Stand KOACH provides the same air quality in a much smaller footprint and at a fraction of the cost for localized needs.

C-645-F vs C-900-F: Model Comparison

Both models deliver the same ISO Class 1 performance. The main differences are size and the maximum distance between the two units.

SpecificationC-645-FC-900-F
External Dimensions (W × D × H)29.80 × 13.03 × 63.43 in37.76 × 13.82 × 63.43 in
Air-Blowing Surface23.39 × 27.56 in35.43 × 27.56 in
Weight (pair)Approx. 353 lbsApprox. 410 lbs
Max Clean Zone DistanceUp to 71 in (without table)Up to 90 in (with table)
Airflow Velocity~19.7 in/s~19.7 in/s
Cleanliness ClassISO Class 1ISO Class 1
Power Consumption (120V)500–1200 W600–1500 W
Filter TypeFERENA nanofiber + pre-filterFERENA nanofiber + pre-filter

Where the Stand KOACH Is Used

These systems are designed for environments that require high cleanliness but cannot always justify a full cleanroom.

  • Semiconductor process development and wafer inspection
  • Pharmaceutical compounding and sterile sample handling
  • Precision optics assembly and metrology
  • Aerospace component manufacturing
  • Food industry quality control and packaging research
  • University and industrial research laboratories.

Conclusion

The Stand KOACH C-645-F and C-900-F give laboratories and manufacturers a practical way to achieve ISO Class 1 cleanliness exactly where it is needed.

By combining high-performance nanofiber filtration with an open, portable design, these systems remove the traditional trade-offs between cleanliness, access, and cost.

Whether you are protecting sensitive semiconductor wafers, preparing sterile pharmaceutical samples, or assembling precision components, the Stand KOACH delivers a controlled clean environment without the expense and rigidity of a full cleanroom.

For facilities that value flexibility and performance, it is a proven and efficient solution.

Frequently Asked Questions (FAQs)

1. How quickly does the Stand KOACH reach ISO Class 1?

The system typically reaches ISO Class 1 cleanliness in less than two minutes after start-up.

2. Can operators work face-to-face?

Yes. The open design allows multiple people to work across the table without walls or barriers blocking access.

3. What size particles does the FERENA filter remove?

The nanofiber filter captures particles as small as 0.1 micrometers, which includes many virus-sized particles.

4. Is the installation complicated?

No permanent installation is required. Place the two units facing each other, plug them in, and turn them on. Casters make repositioning easy.

5. Which model should I choose?

Select the C-645-F for compact workspaces or lighter equipment. Choose the C-900-F when you need a wider clean zone for larger tools or multiple operators working together.