AP95 Ultrapure Cleanroom Fogger – High Volume LN₂ Fogging for Cleanroom Smoke Studies & Airflow Validation

AP95 LN₂ Ultrapure Cleanroom Fogger with rolling, stainless steel enclosure, ≈ 19–20 M³ / Min. ultrapure fog, ≈ 25–35 ft. visual distance, ≈ 1600–1800 M³ fog during typical 85–95 minute operation cycle to visualize airflow turbulence in medium-to-large Clean Rooms, ISO Suites and Barrier Isolators. Dual 80mm fog outlets with velocity control and volume control.

Dewar Storage Tanks & On-Demand Boil-Off Pressure

AP Series LN2 Fogger Product Sheet

$0.00

Description

AP95 Ultrapure Cleanroom Fogger – High Volume LN₂ Fogging for Cleanroom Smoke Studies & Airflow Validation

AP95 Ultrapure Fogger for ISO Cleanroom Validation, Airflow Visualization & Smoke Studies

The AP95 Ultrapure Cleanroom Fogger is a high-performance LN₂ fogging system engineered for medium-to-large cleanroom environments, delivering exceptional fog density, extended runtime, and long-range airflow visualization.

Using Applied Physics’ proven ultrapure fogging technology, the AP95 generates a dense, residue-free fog using Liquid Nitrogen (LN₂) and DI / WFI water, enabling precise visualization of airflow patterns, turbulence, dead zones, and contamination pathways in:

  • Pharmaceutical cleanrooms (USP <797>, <800>)
  • Semiconductor fabrication facilities
  • Biotechnology and life sciences environments
  • ISO 14644 classified cleanrooms

The AP95 produces ultrapure fog with no residue, no contamination, and no cleanup required, making it ideal for critical environments.


AP95 Performance Overview

  • Fog Output Volume:19–20 m³/min
  • Fog Density:1900–2000 ml/min
  • Operating Time:85–95 minutes
  • Visual Fog Distance:25–35 feet
  • Fog Outputs: Dual 80mm outlets
  • System Type: Dewar-Style LN₂ System

Dewar-Style LN₂ Fogger – Proven Reliability in Cleanroom Environments

The AP95 utilizes a dewar-style LN₂ system, a time-tested and widely accepted approach for cleanroom smoke studies and airflow visualization.

How Dewar Systems Work

Dewar-style foggers operate using natural LN₂ evaporation, where liquid nitrogen transitions to gas and creates internal pressure used to drive fog production.

This passive process creates a stable and predictable fog generation system without reliance on active pressurization components.


Benefits of Dewar-Style Systems in Cleanroom Applications

1. Proven, Industry-Trusted Technology

Dewar systems have been used for decades in:

  • Pharmaceutical validation environments
  • Semiconductor fabs
  • Cleanroom certification processes

Their reliability and simplicity make them a trusted standard across regulated industries.


2. Stable and Predictable Performance

Because dewar systems rely on natural LN₂ behavior, they provide:

  • Consistent fog generation under standard operating conditions
  • Predictable performance across validation cycles
  • Repeatable results for documentation and compliance

3. Simplicity and Reliability

Dewar systems have:

  • Fewer active components
  • No mechanical pressurization systems
  • Lower system complexity

This results in:

  • Reduced maintenance requirements
  • Increased system reliability
  • Fewer potential failure points during critical testing

4. Cleanroom Compatibility

Dewar-style systems are well suited for cleanroom environments because they:

  • Operate without introducing additional mechanical complexity
  • Maintain a clean, controlled fog generation process
  • Integrate easily into existing validation protocols

5. Controlled Fog Output for Validation Work

The passive nature of dewar systems allows for:

  • Smooth fog delivery
  • Controlled airflow visualization
  • Accurate identification of turbulence and dead zones

This is particularly important for:

  • ISO 14644 airflow visualization
  • USP <797> compliance testing
  • GMP validation procedures

6. Efficient for Medium-to-Large Environments

When properly engineered—as in the AP95—dewar systems can:

  • Deliver high fog density
  • Maintain extended runtime
  • Provide strong visual coverage across larger cleanroom spaces

Why Dewar Systems Still Matter

While newer technologies exist, dewar-style systems remain widely used because they offer:

  • Reliability over complexity
  • Consistency over variability
  • Proven performance in regulated environments

For many validation teams, this translates to:

  • Greater confidence during audits
  • Easier repeatability of results
  • Reduced operational risk

AP95 – Optimized Dewar Performance

The AP95 is engineered to maximize the strengths of dewar-style fogging, delivering:

  • High fog density (~2000 ml/min)
  • Strong airflow visualization (25–35 ft)
  • Extended runtime (up to ~95 minutes)
  • Dual 80mm outputs for flexible application

This makes it ideal for:

  • Medium-to-large cleanroom smoke studies
  • Controlled airflow validation
  • Repeatable compliance testing

Applications of the AP95 Fogger

  • Cleanroom smoke studies (ISO 14644-3 Annex B7)
  • USP <797> airflow verification
  • HEPA filter validation
  • Laminar flow testing
  • Turbulence and dead zone detection
  • Airflow pattern mapping
  • Semiconductor airflow validation
  • Pharmaceutical cleanroom certification

Fog Density – The Critical Performance Metric

Fog density determines:

  • Visibility distance
  • Clarity of airflow patterns
  • Accuracy of validation results

With ~1900–2000 ml/min, the AP95 provides:

  • Long visible airflow paths
  • Clear turbulence visualization
  • Improved documentation quality
  • More accurate airflow modeling

AP95 vs Other AP Series Foggers

Model Fog Volume Fog Density Runtime Distance Best Use
AP30 ~6–7 m³/min ~600–700 ml/min ~60 min ~15–20 ft Small rooms
AP50 ~10–12 m³/min ~1000–1200 ml/min ~75 min ~18–25 ft Medium rooms
AP95 ~19–20 m³/min ~1900–2000 ml/min ~85–95 min ~25–35 ft Medium–Large rooms
AP100 ~20+ m³/min ~2000+ ml/min ~90 min ~30–40 ft Large rooms
AP200 ~40+ m³/min ~4000+ ml/min ~100+ min ~30–50 ft Massive facilities

What Liquids Are Used

  • Liquid Nitrogen (LN₂)
  • De-ionized Water (DI)
  • Sterile Water
  • Water for Injection (WFI)

Produces:

  • 2–3 micron ultrapure fog
  • Zero residue
  • Zero contamination
  • No cleanup required

When Should You Choose the AP95?

Choose the AP95 when:

  • You need high fog output without moving to AP100
  • You are working in medium-to-large cleanrooms
  • You require reliable, repeatable validation results
  • You want a proven dewar-style system with strong performance

AP95 – Proven Technology, High Performance

The AP95 combines:

  • Proven dewar-style reliability
  • High fog density
  • Extended runtime
  • Strong airflow visualization

It is engineered for teams that need consistent, dependable performance in critical cleanroom validation environments.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.