Description
The Kanomax Multichannel Anemometer PRO – Model 1590 is the world’s most accurate and responsive multichannel anemometer. With accuracy and responsiveness that encompasses the entire air velocity range, including the breeze speed range, this instrument provides the highest level of accuracy in the world. Multipoint measurement on up to 144 channels is realized with the industry’s smallest level miniature probe, high heat resistance, and temperature measurement. Due to the high portability of the main unit and the enhanced interface, this unit provides simultaneous measurement of multiple points in a shorter time, more easily, and ease of use. By connecting an optional analog unit (Model 1592-00), it is possible to record measurement results to your data logger. Each analog unit has 12 channels, and the electric current or voltage can be selected for each channel. A maximum of 12 units and 144 channels can be added to a single main unit, making it ideal for data collection when using a data logger. This product comes with a Windows version of the measurement software. Simultaneous measurement of all channels of air velocity, temperature and humidity, and real-time graph display. The measurement data is saved in text format and can be easily imported into table measurement software such as Excel. There are two types of communication interfaces, USB and LAN. There are two ways to configure the settings: by operating the touch panel on the main unit, or remotely from a PC via USB or LAN.
Features & Benefits
- 15 types of compatible probes for various applications
- The smallest class probes in the industry
- High heat resistance enables precise measurement even in tough environments
- Large-scale system configuration with up to 144 channels available
- Easily measure in large-scale spaces
- Highly portable main body makes it easy to use in vehicles
- Improved probe response and accuracy, micro air velocity limit of 0.01 m/s
- Support analog output via optional Analog Unit - Model 1592-00
- Windows measurement software simultaneously measures air velocity, temperature, and humidity via the real-time graph display. Measurement data is saved in text format and can be easily imported into table measurement software such as Excel
Applications
- Thermal management of automobile electronic control unit (ECU)
- Electronic component heat evaluation
- Indoor airflow management for semiconductor manufacturing equipment
- Data center thermal management
Specifications
Main Unit Specifications
Product | Multi-Channel Anemomaster PRO Main Unit | ||
---|---|---|---|
Model | 1590-00 | ||
Display, Operation | 7-inch color LCD with touch panel | ||
Communication Function | Data | USB Type-A: For USB memory | |
Remote Measurement | Modbus (Ethernet, USB Serial) | ||
Between Units | RS485 (Standard cable) | ||
Recording Media | Medium | Built-in memory | |
Format | CSV format | ||
Recording Capacity | 8GB (One hub unit can measure 1000 sampling times, about 24500 times). | ||
External Trigger Input | Pin jack terminal Φ2.5 audio jack (Edge detection at start) | ||
Language | Japanese, English, Chinese | ||
Power Supply | DC12 to 24V (Select either one of 3 options below)
1) Connection with other unit, 2) AC adaptor (90W), 3) DC power cable |
||
Power Consumption | Up to 50W | ||
Operating Environment | 5~40℃, 0~85% RH (No Condensation) | ||
Storage Environment | -10~60℃, 0~90% RH (No Condensation) |
||
Dimensions | W220mm × D130mm × H40mm | ||
Weight | 0.6 kg | ||
Standard Accessories | AC Adapter (90W), Software (CD), Operation manual, USB cable, Rubber cap | ||
Warranty | 1 year |
Hub Unit Specifications
Product | Multi-Channel Anemomaster HUB Unit | ||
---|---|---|---|
Model | 1591-00 | ||
Number of Channels | 12ch | ||
Communication Function | Between Probes | Serial communication (standard cable) | |
Between Probes | Serial communication (standard cable, connector) | ||
Between Probes | RS485 (Standard cable) | ||
Power Supply | DC12 ~ 24V | ||
Power Consumption | Power supply conforms to the main unit | ||
Dimensions | W220mm × D130mm × H40mm | ||
Weight | 0.5 kg | ||
Standard Accessories | Setup guide, Connecting clips (2pcs) | ||
Warranty | 1 year |
Analog Unit Specifications
Product | Analog Unit | ||
---|---|---|---|
Model | 1592-00 | ||
Number of Channels | 12 | ||
Communication Function | Between units | Serial communication {connector} | |
Analog Output | Voltage output | Range | 0 ~ 5 V |
Output resistance | 1 kΩ | ||
Current output | Range | 4 ~20 mA | |
Load resistance | 250 Ω | ||
Power Supply | DC12 to 24V (Select either one of 3 options below)
1) Connection with other unit, 2) AC adaptor (90W), 3) DC power cable |
||
Power Consumption | 10W | ||
Operating Environment | 5~40℃, 0~85% RH (No Condensation) | ||
Storage Environment | -10~60℃, 0~90% RH (No Condensation) | ||
Size | W220mm × D130mm × H40mm | ||
Weight | 0.5kg | ||
Standard Accessories | Setup guide, Connecting clips (2pcs), Rubber cap (2pcs), Terminal block (3pcs) | ||
Warranty | 1 year |
Probe Specifications
Model Number | Measurement Target | Directivity | Air Velocity | Wind Temperature | Humidity | Operating Temperature |
Temperature Compensation Sensor |
||||
---|---|---|---|---|---|---|---|---|---|---|---|
Measurement Range | Measurement Accuracy | Responsivity | Measurement Range | Measurement Accuracy | Measurement Range | Measurement Accuracy | |||||
0972-00 0973-00 |
Wind Speed |
Yes | 0.01~50.0m/s | The larger of ± 2% or ± 0.02 m/s of the displayed value |
1 Second | ー | ー | ー | ー | 0-100℃ | ± 5% of displayed value at 0-100 ℃ |
0975-00 | No | 0.01~25.0m/s | 3 Seconds | ||||||||
0975-09 0975-10 |
0.01~50.0m/s | ||||||||||
± 5% of displayed value at 0-120 ℃ |
|||||||||||
0976-03 0976-04 0976-07 |
0.01~30.0m/s | The larger of ± 3% or ± 0.02 m / s of the displayed value |
0-120℃ | ||||||||
0976-13 0976-14 0976-17 |
The larger of ± 2% or ± 0.02 m/s of the displayed value |
0-100℃ | ± 5% of displayed value at 0-100 ℃ |
||||||||
0976-05 | Air Velocity and Temperature | The larger of ± 3% or ± 0.02 m/s of the displayed value |
0~120℃ | ±0.5% | 0-120℃ | ± 5% of displayed value at 0-120 ℃ |
|||||
0976-15 | 0~100℃ | 0-100℃ | ± 5% of displayed value at 0-100 ℃ |
||||||||
0975-21 | The larger of ± 2% or ± 0.02 m/s of the displayed value |
||||||||||
0975-31 | Air Velocity, Temperature and Humidity |
0.01~25.0m/s | 0~60℃ | 5~95%RH | 5~80% RH:3% RH 80~90% RH:5% RH |
Resources
User Manual
Data Sheet
Accessories
- Flat Probe (V) - Model 0972-00
- Uni-Directional Probe (V) - Model 0973-00
- Needle Probe (V) - Model 0975-00
- Needle Probe (V) - Model 0975-09
- Long Needle Probe (V) - Model 0975-10
- Spherical Probe (V) - Model 0976-03
- Spherical Angled Probe (V) - Model 0976-04
- Mini Probe (V/T) - Model 0976-05
- Mini Probe (V) - Model 0976-07
- Spherical Probe (V) - Model 0976-13
- Spherical Angled Probe (V) - Model 0976-14
- Mini Probe (V/T) - Model 0976-15
- Mini Probe (V) - Model 0976-17
- Needle Probe (V/T) - Model 0975-21
- Probe (V/T/H) - Model 0975-31
- Spare AC Adaptor - Model 1580-10
- DC Power Connection - Model 1580-37
- Probe Fixture Jig Pack (20pcs.; compatible w/ 0976-03/0976-04 and 0976-13/0976-14) - Model 1580-90
- Double Coated Tape (for 0976 probes) - Model 1590-92
- Standard Cable (0.5m) - 1580-30
- Standard Cable (2m) - 1580-31
- Standard Cable (5m) - 1580-32
- Standard Cable (10m) - 1580-33
- Standard Cable (20m) - 1580-34
- Standard Cable (40m) - 1580-35