Description
High Performance Liquid Chromatography System EClassical 3200
Features:
1. Classic, inherited product reliability for more accurate and consistent results.
2. Professional, national standard technology leader, making more effective and applicable.
3. Eficient, perfectly superb compatibility makes more convenient and easier.
O3220 Column Oven
Temperature range
Ambient+5~85℃
Accuracy
≤±0.5℃
Precision
≤0.1℃
Power Supply
AC220V±10%, 50Hz/130W
Dimensions/Weight
440*160*470mm/11kg
P3210 High Pressure Constant Flow Pump
Flow Range
0.001~10.000 mL/min (step 0.001 mL/min)
Accuracy
≤±2.0%(0.001mL/min~10.000mL/min)
Precision
≤0.1%(0.100mL/min~10.000mL/min)
Pressure Range
0~70MPa
Communication Method
UDP Network Communication
Power Supply
AC220V±10%, 50Hz/100W
Dimensions/Weight
440*380*180mm/13kg
P3220 High Pressure Constant Flow Pump
Flow Range
0.001~10.000 mL/min (step 0.001 mL/min)
Accuracy
≤±2.0%(0.001mL/min~10.000mL/min)
Precision
≤0.1%(0.100mL/min~10.000mL/min)
Pressure Range
0~70MPa
Communication Method
UDP Network Communication
Power Supply
AC220V±10%, 50Hz/300W
Dimensions/Weight
440*380*180mm/18kg
P3230 Low Pressure Quaternary Pump
Flow Range
0.001~10.000 mL/min (step 0.001 mL/min)
Accuracy
≤±2.0%(0.001mL/min~10.000mL/min)
Precision
≤0.1%(0.100mL/min~10.000mL/min)
Pressure Range
0~70MPa
Communication Method
UDP Network Communication
Power Supply
AC220V±10%, 50Hz/150W
Dimensions/Weight
440*380*180mm/13kg
D3210 UV-Vis Detector
Linearity
≥2.0AU
Wavelength Range
190~800nm
Wavelength Repeatability
±0.1nm
Wavelength Accuracy
±1.0nm
Noise
≤1.5×10-5AU (Single wavelength)
Drift
≤2.0×10-4 AU (Single wavelength)
Light Source
Deuterium lamp, tungsten lamp
Optical Path
Dual wavelength
Response Time
0.1~5s
Sampling Frequency
5Hz/10Hz/20Hz/50Hz; Double wavelength 1Hz
Cell
Optical path 10mm; Pressure 1000psi
Communication Method
UDP Network Communication
Power Supply
AC220V±10%, 50Hz/100W
Dimensions/Weight
440*380*160mm/10kg
D3230 DAD Detector
Linearity
≥2.0AU
Wavelength Range
190~800nm
Wavelength Repeatability
±0.1nm
Wavelength Accuracy
±1.0nm
Noise
≤1.0×10-5AU
Drift
≤3.0×10-4 AU
Light Source
Deuterium lamp (tungsten lamp optional)
Exposure Time
25ms, 50ms, 100ms
Sampling Frequency
5Hz (2, 10, 20)
Cell
Optical path 10mm; Pressure 8MPa
Communication Method
UDP Network Communication
Power Supply
AC220V±10%, 50Hz/100W
Dimensions/Weight
440*380*160mm/10kg
Technical Parameters:
Model
EClassical 3200 (Type I)
EClassical 3200 (Type II)
EClassical 3200 (Type III)
EClassical3200 (Type IV)
EClassical 3200 (Type V)
Pump
P3210*1
P3220*1
P3230*1
P3220*1
P3230*1
Detector
D3210*1
D3230*1
Sample Cell
SC3210A
SC3230A
Solvent Bottle Tray
T3200*1
Sampler Injector
Rheodyne 7725i*1
Column
Supersil ODS2 5μm 4.6*250mm*1
Workstation
Kromstation*1
Valve Mounting Frame
VB3200*1
Multifunctional Mounting Frame
MB3200*1
Column Mounting Frame
CB3200*1
System Toolkit
EClassical 3200*1
Power Supply
AC220V±10%, 50Hz
Optional Accessory
Auto-sampler, column, column oven, evaporative light scattering detector, differential refractive index detector, fluorescence detector, solvent bottle
Packing Size (W*D*H)
580*470*370mm, 580*470*370mm, 490*350*100mm, 580*470*370mm
Gross Weight
22kg, 14kg, 4kg, 12kg
22kg, 14kg, 4kg, 13kg
22kg, 14kg, 4kg, 8kg
22kg, 15kg, 4kg, 13kg
22kg, 15kg, 4kg, 18kg











Reviews
There are no reviews yet.