Auto ELISA Processor AP Medical4001
Features:
1. Adopt the principle of pressure type liquid detection.
2. With TIP detection, clot detection function.
3. High-precision pipetting, the lowest volume can reach 5μl.
4. Position sensing, real-time monitoring of gripper status.
5. Multi-spacing and multi-strength adjustable grippers can be adapted to grasp and place.
microplates and plate covers of different sizes.
6. Dual thread control, can run simultaneously with the sampling arm without interfering with each other.
Technical Parameters:
Model
AP Medical4001
Sample&Reagent Unit
Sample Racks
12*16 push-pull sample rack with detection
Sampling Channel
4 channels
Liquid Level Detection
Air pressure level detection, clot detection function
Tip
1000μl, 5 tip racks
Pipetting
5μl~1000μl
Pipetting Precision
100μl: CV≤1.0%, Accuracy≤2.0%
1000μl: CV≤0.5%, Accuracy≤1.0%
Reagent Position
6 reagent racks, reagent tanks with detection
Washing Unit
Washer
2 units
Washing Head
16-channel(32-pin), double row cleaning, hanging installation, with leakage recovery
Injection Uniformity
CV<1.5%
Washing Residual
<1μl
Reading Unit
Reading Channels
8 independent photometric channels, mono and dichromatic reading
Linear Range
0.000~3.000Abs
Repeatability
CV≤1.0%
Stability
≤±0.003Abs
Optical Filters
4 standard filters(405, 450, 492, 630nm)
Total 10 filters positions
Reading Accuracy
≤±0.02Abs from 0.0 to 1.0OD
≤±0.03Abs from 1.0 to 2.0OD
Sensitivity
≥0.01mg/L
Channel Difference
≤0.02Abs
Incubation Unit
Incubators
12 shaking incubators
Cover Positions
2(12 covers)
Heating Method
Dry heating with cover
Shaking Function
Horizontal circular oscillation, 1~3 levels adjustable, amplitude 2.5mm
Temperature Range
RT to 60 °C
Temperature Uniformity
0.5℃
Temperature Fluctuation
±0.5℃
Data Management
Software
Above Windows 7 system
LIS System
Bi-direction, support HL7 protocol
Results
Absorbance and results reviewable by software
Printer
External optional
Built-in Scanner
Optional
Other Function
Biosafety Protection
Optional(Negative pressure working zone, HEPA filter)
Disinfection
UV lamp
Lighting
LED
IAP Function
Firmware can be upgraded online at any time
Working Condition
Power Supply
AC220V±10%, 50/60Hz(Standard); 110V±10%, 60Hz(Optional)
Temperature
10~40℃
Humidity
30~80%
Size&Weight
External Size (W*D*H)
1775*190*1683mm
Net Weight
445kg
Package Size(W*D*H)mm
Machine: 1945*950*1150
Base Stand: 1945*950*995
Accessories: 1370*930*530
Gross Weight(kg)
Machine: 364.5
Base Stand: 208.5
Accessories: 97