Description
Automatic Nucleic Acid Extraction System BK-AutoHS96
Features:
1. Accurate pipetting, air pressure correction can adapt to extreme environments such as flat ground, plateau, island, etc., to ensure the accuracy of pipetting.
2. 96 samples can be processed within 60 minutes, realizing high-throughput processing of samples, saving time and effort.
3. Reagent position and PCR plate position, can be refrigerated at 4℃.
4. With high-efficiency filter, ultraviolet disinfection and sterilization, and safety door functions, effectively prevent microbial pollution.
5. Multi-threaded control and three-module extraction can run three different extraction programs at the same time.
6. Intelligent temperature control, over-temperature protection function.
7. Preset multiple experimental programs, strong compatibility, suitable for various types of sample graphic guides, visualized operations.
8. Nucleic acid products can be allocated to the 2*96 PCR reaction system to flexibly construct a variety of different PCR detection systems.
Technical Parameters:
Model
BK-AutoHS96
Extraction Method
Magnetic bead method
Working Mode
Automatic sampling+Nucleic acid extraction+PCR reaction system addition
Throughput
1~96, linear slide type sample rack
Extraction Volume
20~1000μl
Processing Time
Complete the processing of 96 samples within 60 minutes(Related to reagents)
Magnetic Bead Recovery
≥98%
Temp Range
RT~105℃, lysis and elution position
Temp Accuracy
0.1℃
Heating Method
Dry bath heating
Heating Speed
RT~100℃≤6min
Shaking Function
Up and down oscillation(1~5 APM adjustable)
Extraction Position
6(96-well deep well plate)
Robotic Arm
A robotic arm for adding samples and reagents
Pipetting Channel
2 channels
Liquid Detection
Pneumatic liquid level detection principle, intelligent detection of blocked needle
Pipetting Tip
50μl, 200μl,1000μl, disposable black conductive needle with filter element
Tip Amount
2~3 tips/sample
Pipetting Accuracy
10μl, CV≤3.0%, Accuracy≤5.0%, 50μl tip
50μl, CV≤2.0%, Accuracy≤2.0%, 1000μl tip
100μl, CV≤1.5%, Accuracy≤2.0%, 1000μl tip
Sample Volume
2~1000μl
Working Zone
2 pcr positions with cooling function
6 tip positions for three types of tips
2 reagent positions(5ml freezing tube rack position with cooling function, one reserved position)
Protective Function
Start up self-test, Power-off protection, High temperature alarm, Over-temperature protection, Tip removal protection
Disinfection Method
UV lamp(30W*1, 8W*1)
Illumination Lamp
10W LED lamp
Audible Alarm
Yes(Red and blue blinking)
Safety Door Design
With safety lock function, the safety door is opened and the program is suspended
Display
10.1 inch touch screen, Windows system
Scanning
Optional
Interface
LAN interface(Bi-direction LIS optional)
Contamination Control
Built-in air duct and HEPA filter can effectively filter internal aerosols and prevent cross-contamination
IAP Function
Firmware can be upgraded online at any time
Power Supply
110/220V, 50/60Hz
External Size(W*D*H)
1420*850*1842mm
Package Size(W*D*H)
1535*970*1180mm(Main instrument);
1540*970*1160mm(Base)
Gross Weight
360kg(Main instrument);
190kg(Base)











Reviews